A Semi-Open-Loop, High-Robust Preamplifier for Hall Sensor with Optimized Transconductance Match

A low-cost, high-robust, high-gain preamplifier is fabricated in a 65 nm CMOS for Hall sensors. A semi-open loop that combines an optimized differential–difference amplifier with a simplified open-loop amplifier is proposed to achieve stringent transconductance matching, with the same DC and AC conditions. A two-stage reconfigurable structure, together with an embedded offset-accumulation elimination scheme, relieves open-loop stress and achieves both high fidelity and accurate gain. The experimental results show that the preamplifier has a variable gain of 34.6–46.6 dB and a gain error no more than 0.12% under process/voltage/temperature variations and without error calibration, at the cost of an active area of 0.076 mm2 and a current dissipation of 0.7 mA under a 2.5–3.3 V supply. Specifically, both the loop topology and the transconductance match are different from the existing works.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-05-01
DOI
https://doi.org/10.3390/electronics15091918
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Semi-Open-Loop, High-Robust Preamplifier for Hall Sensor with Optimized Transconductance Match

Yuyang Ding, Xukun Wang, Bo Zhou, Chen Wang
Electronics
Magnetic Field Sensors Techniques
article

A Semi-Open-Loop, High-Robust Preamplifier for Hall Sensor with Optimized Transconductance Match

Yuyang Ding, Xukun Wang, Bo Zhou, Chen Wang
article en

Abstract

A low-cost, high-robust, high-gain preamplifier is fabricated in a 65 nm CMOS for Hall sensors. A semi-open loop that combines an optimized differential–difference amplifier with a simplified open-loop amplifier is proposed to achieve stringent transconductance matching, with the same DC and AC conditions. A two-stage reconfigurable structure, together with an embedded offset-accumulation elimination scheme, relieves open-loop stress and achieves both high fidelity and accurate gain. The experimental results show that the preamplifier has a variable gain of 34.6–46.6 dB and a gain error no more than 0.12% under process/voltage/temperature variations and without error calibration, at the cost of an active area of 0.076 mm2 and a current dissipation of 0.7 mA under a 2.5–3.3 V supply. Specifically, both the loop topology and the transconductance match are different from the existing works.

ElectronicsVol. 15(9)
Beijing Institute of Technology (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 9%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.