Detective quantum efficiency of the Timepix4 hybrid pixel detector and its application to parallel-beam diffraction

The detective quantum efficiency (DQE) and normalised noise power spectrum (NNPS) of the Timepix4 hybrid pixel detector in event-driven mode in TEM have been measured at 100 kV and 200 kV. In a raw data readout mode, the zero-frequency DQE exceeds 0.9 at both 100 kV and 200 kV. At the Nyquist frequency, the DQE remains above 0.2 at 100 kV but drops close to zero at 200 kV. Initial parallel-beam diffraction data from a polycrystalline gold nanoparticle sample is reported which shows that at 200 kV Timepix4 can detect weak diffracted information beyond a 75 mrad half-angle.

Authors

Institutions

Publication Details

Journal
Ultramicroscopy
Published
2026-04-30
DOI
https://doi.org/10.1016/j.ultramic.2026.114376
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detective quantum efficiency of the Timepix4 hybrid pixel detector and its application to parallel-beam diffraction

R. Plackett, Giulio Crevatin, Liam O'ryan, Marcus Gallagher-Jones et al.
Ultramicroscopy
Particle Detector Development and Performance
article

Detective quantum efficiency of the Timepix4 hybrid pixel detector and its application to parallel-beam diffraction

R. Plackett, Giulio Crevatin, Liam O'ryan, Marcus Gallagher-Jones, J. S. Barnard, Angus I. Kirkland, Zhiyuan Ding, Nina Dimova, Daniela Bortoletto
article en

Abstract

The detective quantum efficiency (DQE) and normalised noise power spectrum (NNPS) of the Timepix4 hybrid pixel detector in event-driven mode in TEM have been measured at 100 kV and 200 kV. In a raw data readout mode, the zero-frequency DQE exceeds 0.9 at both 100 kV and 200 kV. At the Nyquist frequency, the DQE remains above 0.2 at 100 kV but drops close to zero at 200 kV. Initial parallel-beam diffraction data from a polycrystalline gold nanoparticle sample is reported which shows that at 200 kV Timepix4 can detect weak diffracted information beyond a 75 mrad half-angle.

UltramicroscopyVol. 284
University of Oxford (GB), Research Complex at Harwell (GB), Rosalind Franklin Institute (GB)
Rosalind Franklin Institute, UK Research and Innovation, HORIZON EUROPE Framework Programme, Science and Technology Facilities Council
Affordable and clean energy
Openalex Percentile: Top 9%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.