Subject-Specific Comparative Performance Analysis of Deep Learning Architectures for Motor Imagery Classification

Motor Imagery (MI)-based brain–computer interfaces (BCIs) offer promising solutions for enhancing communication and motor functions in individuals with neurological impairments. However, decoding EEG signals accurately is difficult because of their poor signal-to-noise ratio and variability across subjects and sessions. In addition, EEG signals are sensitive to noise. Moreover, the low spatial resolution of EEG signals makes model generalization unreliable due to differences between signals across subjects. While several deep learning models have been developed, a fair comparison remains difficult due to differences in pre-processing, training procedures, and evaluation protocols. This study provides a systematic, controlled comparison of five deep learning approaches for subject-specific classification—EEGNet, EEG-TCNet, ShallowConvNet, DeepConvNet, and CTNet—using the BCI Competition IV datasets 2a and 2b. To enable an unbiased comparison, all models are trained using the same pipeline, with uniform pre-processing and training. Apart from classical accuracy scores, the effect of a constant set of hyper-parameters on the training dynamics, generalization capacity, and the susceptibility to overfitting is evaluated. The performance of the above-stated models is evaluated based on training dynamics, computational efficiency, accuracy, and the quality of the features learned by the models. Using the five-dimensional analysis framework consisting of quantitative performance metrics, training curves, confusion matrix analysis, ROC analysis, and t-SNE visualization techniques, the performance of the brain–computer interfaces is comprehensively analyzed. The experimental analysis confirms that CTNet outperforms other models, with accuracy values of 82.56% and 86.42% on the BCI competition IV datasets 2a and 2b, respectively. The EEGNet model is recognized as having the most potential in the field of real-time applications, owing to its light structure; meanwhile, the DeepConvNet model shows signs of overfitting, despite showing good accuracy. These findings highlight that model training characteristics and sensitivity to the hyper-parameters are important factors in evaluating deep learning models for MI-EEG classification problems.

Authors

Institutions

Publication Details

Journal
Mathematics
Published
2026-04-30
DOI
https://doi.org/10.3390/math14091527
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Subject-Specific Comparative Performance Analysis of Deep Learning Architectures for Motor Imagery Classification

Rito Clifford Maswanganyi, Bandile Mdluli, Philani Khumalo
Mathematics
EEG and Brain-Computer Interfaces
article

Subject-Specific Comparative Performance Analysis of Deep Learning Architectures for Motor Imagery Classification

Rito Clifford Maswanganyi, Bandile Mdluli, Philani Khumalo
article en

Abstract

Motor Imagery (MI)-based brain–computer interfaces (BCIs) offer promising solutions for enhancing communication and motor functions in individuals with neurological impairments. However, decoding EEG signals accurately is difficult because of their poor signal-to-noise ratio and variability across subjects and sessions. In addition, EEG signals are sensitive to noise. Moreover, the low spatial resolution of EEG signals makes model generalization unreliable due to differences between signals across subjects. While several deep learning models have been developed, a fair comparison remains difficult due to differences in pre-processing, training procedures, and evaluation protocols. This study provides a systematic, controlled comparison of five deep learning approaches for subject-specific classification—EEGNet, EEG-TCNet, ShallowConvNet, DeepConvNet, and CTNet—using the BCI Competition IV datasets 2a and 2b. To enable an unbiased comparison, all models are trained using the same pipeline, with uniform pre-processing and training. Apart from classical accuracy scores, the effect of a constant set of hyper-parameters on the training dynamics, generalization capacity, and the susceptibility to overfitting is evaluated. The performance of the above-stated models is evaluated based on training dynamics, computational efficiency, accuracy, and the quality of the features learned by the models. Using the five-dimensional analysis framework consisting of quantitative performance metrics, training curves, confusion matrix analysis, ROC analysis, and t-SNE visualization techniques, the performance of the brain–computer interfaces is comprehensively analyzed. The experimental analysis confirms that CTNet outperforms other models, with accuracy values of 82.56% and 86.42% on the BCI competition IV datasets 2a and 2b, respectively. The EEGNet model is recognized as having the most potential in the field of real-time applications, owing to its light structure; meanwhile, the DeepConvNet model shows signs of overfitting, despite showing good accuracy. These findings highlight that model training characteristics and sensitivity to the hyper-parameters are important factors in evaluating deep learning models for MI-EEG classification problems.

MathematicsVol. 14(9)
Durban University of Technology (ZA)
Openalex Percentile: Top 6%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.