To address the issue of motion artifact interference faced by wearable ECG monitoring devices in dynamic environments, this paper proposes an adaptive motion artifact removal framework based on improved Variational Mode Decomposition (VMD). By designing a parameter self-adjustment mechanism and a multi-feature fusion mode selection strategy, the algorithm’s adaptability to non-stationary ECG signals and noise separation accuracy are enhanced. Experiments on the MIT-BIH Arrhythmia Database demonstrate that the improved VMD algorithm outperforms traditional wavelet transform, Recursive Least Squares (RLS), and conventional VMD methods in multiple performance metrics. Specifically, the signal-to-noise ratio (SNR) is improved by 5.17 dB, the Percentage Root Mean Squared Difference (PRD) is reduced to 49.13%, the correlation coefficient is increased to 0.88, and high real-time processing capability (Real-Time Processing Ratio, RTR = 22.5) is maintained, meeting the low-latency requirements of wearable devices. Moreover, case studies on pathological recordings (e.g., Wolff–Parkinson–White syndrome and third-degree atrioventricular block) reveal that the improved VMD better preserves clinically significant features such as delta waves and dissociated P waves. Furthermore, a downstream arrhythmia classification task using a CWT-CNN classifier achieves 91.67% accuracy on denoised heartbeats, which is 2.67 percentage points higher than that on raw noisy signals (89.00%), confirming the practical benefit of the proposed preprocessing for AI-based diagnosis. This study provides an effective processing solution for improving the signal quality of wearable ECG monitoring.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-05-01
DOI
https://doi.org/10.3390/bios16050262
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-Feature Adaptive Variational Mode Decomposition for Wearable ECG Devices

Yuanlin Nie, Zixin Chen, Z.H. Liu, Guanzhou Liu et al.
Biosensors
ECG Monitoring and Analysis
article

Multi-Feature Adaptive Variational Mode Decomposition for Wearable ECG Devices

Yuanlin Nie, Zixin Chen, Z.H. Liu, Guanzhou Liu, Long Mo, Feng He, Liming Peng, Di Wu, Junwei Zhang, Chang Zeng
article en

Abstract

To address the issue of motion artifact interference faced by wearable ECG monitoring devices in dynamic environments, this paper proposes an adaptive motion artifact removal framework based on improved Variational Mode Decomposition (VMD). By designing a parameter self-adjustment mechanism and a multi-feature fusion mode selection strategy, the algorithm’s adaptability to non-stationary ECG signals and noise separation accuracy are enhanced. Experiments on the MIT-BIH Arrhythmia Database demonstrate that the improved VMD algorithm outperforms traditional wavelet transform, Recursive Least Squares (RLS), and conventional VMD methods in multiple performance metrics. Specifically, the signal-to-noise ratio (SNR) is improved by 5.17 dB, the Percentage Root Mean Squared Difference (PRD) is reduced to 49.13%, the correlation coefficient is increased to 0.88, and high real-time processing capability (Real-Time Processing Ratio, RTR = 22.5) is maintained, meeting the low-latency requirements of wearable devices. Moreover, case studies on pathological recordings (e.g., Wolff–Parkinson–White syndrome and third-degree atrioventricular block) reveal that the improved VMD better preserves clinically significant features such as delta waves and dissociated P waves. Furthermore, a downstream arrhythmia classification task using a CWT-CNN classifier achieves 91.67% accuracy on denoised heartbeats, which is 2.67 percentage points higher than that on raw noisy signals (89.00%), confirming the practical benefit of the proposed preprocessing for AI-based diagnosis. This study provides an effective processing solution for improving the signal quality of wearable ECG monitoring.

BiosensorsVol. 16(5)
Central South University (CN), Xiangya Hospital Central South University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 8%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.