Training AI to Improve Distinction of Triple-Negative Invasive Breast Cancer from Cysts and Fibroadenomas on Ultrasound
Background/Objectives: Circumscribed oval, hypoechoic masses are common on screening breast ultrasound (US), and the vast majority are benign. Triple-receptor negative invasive breast cancer (TNBC) can appear similar, resulting in both human and artificial intelligence (AI) interpretive errors. Purpose: We sought to improve AI performance in distinguishing common benign masses from TNBC through a retrospective model refinement and validation study. Materials and Methods: In an Institutional Review Board-approved HIPAA-compliant protocol, from five academic medical centers, orthogonal ultrasound images of 1771 breast masses 2 cm or smaller were acquired, consisting of cysts, complicated cysts, other benign, and malignancies. Cases were randomized, controlling for lesion class, site, and patient age, with 1446 (including 402, 27.8%, malignancies) used for training and 325 (including 95, 29.2% malignancies) for validation using Koios DS® (decision support, KDS) software version 2.0. A breast imaging radiologist from each center reviewed images and recorded BI-RADS features and assessment. Demographics, symptoms, and pathology or at least one-year follow-up was recorded. The KDS score was evaluated standalone and in combination with BI-RADS using logistic regression and ROC analysis with focus on specificity at sensitivity of 98%. Results: In training, KDS standalone performed comparably to BI-RADS, and significantly improved BI-RADS malignancy risk prediction (p < 0.001). The 98%–sensitivity threshold for combined KDS + BI-RADS was estimated and kept fixed during validation. In validation, KDS standalone performed similar to BI-RADS with AUC = 0.97 (CI: 0.95–0.98) versus 0.95 (p = 0.22), with sensitivity of 98% (93/95, CI: 95–100%) for both and specificity of 70.9% (163/230, CI: 65.0–76.7%) for KDS versus 63.9% for BI-RADS (147/230, p = 0.10). Combining KDS + BIRADS significantly improved overall performance (AUC 0.98, p < 0.001) and specificity (74.4%, 171/230, p < 0.001) while maintaining sensitivity at 98% (93/95). Conclusions: While KDS alone should not replace BI-RADS, when used in combination with BI-RADS, it can significantly improve specificity for highly accurate (98% sensitivity) triaging management of masses representative of those seen on screening US.
Authors
- Maham Siddique (ORCID: https://orcid.org/0000-0001-6855-7321)
- Andriy I. Bandos (ORCID: https://orcid.org/0000-0001-5629-1415)
- Regina J. Hooley (ORCID: https://orcid.org/0000-0002-3093-1338)
- Richard Ha (ORCID: https://orcid.org/0000-0003-1704-2875)
- R. Chad McClennan (ORCID: https://orcid.org/0009-0005-8128-036X)
- Yuying Cao
- Samantha L. Heller
- Jeremy M. Berg
- Ajit Jairaj
- Linda H. Larsen
- Wendie A. Berg (ORCID: https://orcid.org/0000-0002-8792-6185)
Institutions
- University of Pittsburgh (US)
- Keck Hospital of USC (US)
- Yale University (US)
- NYU Langone Health (US)
- University of Chicago Medical Center (US)
- Department of Health (TW)
- New York University (US)
- Columbia University (US)
Publication Details
- Journal
- Diagnostics
- Published
- 2026-04-30
- DOI
- https://doi.org/10.3390/diagnostics16091354
- Primary Topic
- Breast Lesions and Carcinomas
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Koios Medical