Headset-Type Biofluorometric Gas Sensor with CMOS for Transcutaneous Ethanol from the Ear Canal

This study presents a headset-type biofluorometric gas sensor incorporating a CMOS camera for continuous, non-invasive monitoring of transcutaneous ethanol from the ear canal. The sensor employs alcohol dehydrogenase (ADH) to catalyze the NAD+-to-NADH conversion during ethanol oxidation, enabling quantitative measurement through NADH fluorescence detection (λex = 340 nm, λem = 490 nm). The integrated system comprises a wireless CMOS camera, an ADH-immobilized cotton mesh enzyme membrane, UV-LED excitation source, optical bandpass filters, and a dual convex lens assembly housed in a 3D-printed headset powered by a lithium battery. Key improvements include a 3.5-fold enhancement in fluorescence collection efficiency achieved through optimized dual convex lens configuration. Systematic screening of seven cotton mesh materials identified Iwatsuki cotton mesh as the optimal enzyme immobilization substrate, exhibiting minimal autofluorescence and 14.2-fold higher water retention capacity compared to H-PTFE membranes. The glutaraldehyde-crosslinked ADH-immobilized cotton mesh maintained enzymatic activity for over 45 min with a 10-fold improvement in signal-to-noise ratio. The system demonstrated a dynamic detection range spanning 10 ppb to 10 ppm for gaseous ethanol and exhibited high selectivity against interfering volatile organic compounds in skin gas, including methanol, acetaldehyde, formaldehyde, and acetone. Human experiments validated the system’s practical performance. Following alcohol consumption, subjects wore the device for 50 min while real-time fluorescence monitoring captured dynamic ethanol concentration changes in the ear canal. The dose-dependent fluorescence response—approximately 2-fold higher at 0.4 g/kg versus 0.04 g/kg alcohol intake—correlated well with calibration data. This headset-type biofluorometric sensor enables unrestrained continuous monitoring of ear canal ethanol, providing a novel wearable platform for alcohol metabolism assessment with potential applications in health monitoring and clinical research.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-04-30
DOI
https://doi.org/10.3390/s26092817
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Headset-Type Biofluorometric Gas Sensor with CMOS for Transcutaneous Ethanol from the Ear Canal

Kenta Ichikawa, Kenta Iitani, Yoshikazu Nakajima, Kohji Mitsubayashi et al.
Sensors
Analytical Chemistry and Sensors
article

Headset-Type Biofluorometric Gas Sensor with CMOS for Transcutaneous Ethanol from the Ear Canal

Kenta Ichikawa, Kenta Iitani, Yoshikazu Nakajima, Kohji Mitsubayashi, Geng Zhang, Di Huang
article en

Abstract

This study presents a headset-type biofluorometric gas sensor incorporating a CMOS camera for continuous, non-invasive monitoring of transcutaneous ethanol from the ear canal. The sensor employs alcohol dehydrogenase (ADH) to catalyze the NAD+-to-NADH conversion during ethanol oxidation, enabling quantitative measurement through NADH fluorescence detection (λex = 340 nm, λem = 490 nm). The integrated system comprises a wireless CMOS camera, an ADH-immobilized cotton mesh enzyme membrane, UV-LED excitation source, optical bandpass filters, and a dual convex lens assembly housed in a 3D-printed headset powered by a lithium battery. Key improvements include a 3.5-fold enhancement in fluorescence collection efficiency achieved through optimized dual convex lens configuration. Systematic screening of seven cotton mesh materials identified Iwatsuki cotton mesh as the optimal enzyme immobilization substrate, exhibiting minimal autofluorescence and 14.2-fold higher water retention capacity compared to H-PTFE membranes. The glutaraldehyde-crosslinked ADH-immobilized cotton mesh maintained enzymatic activity for over 45 min with a 10-fold improvement in signal-to-noise ratio. The system demonstrated a dynamic detection range spanning 10 ppb to 10 ppm for gaseous ethanol and exhibited high selectivity against interfering volatile organic compounds in skin gas, including methanol, acetaldehyde, formaldehyde, and acetone. Human experiments validated the system’s practical performance. Following alcohol consumption, subjects wore the device for 50 min while real-time fluorescence monitoring captured dynamic ethanol concentration changes in the ear canal. The dose-dependent fluorescence response—approximately 2-fold higher at 0.4 g/kg versus 0.04 g/kg alcohol intake—correlated well with calibration data. This headset-type biofluorometric sensor enables unrestrained continuous monitoring of ear canal ethanol, providing a novel wearable platform for alcohol metabolism assessment with potential applications in health monitoring and clinical research.

SensorsVol. 26(9)
Tokyo Medical and Dental University (JP), Institute of Science Tokyo (JP)
Ministry of Education, Culture, Sports, Science and Technology, Japan Society for the Promotion of Science, Japan Science and Technology Agency
Openalex Percentile: Top 10%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.