Influence of Reduced Cortical Bone Compression by Implant Macrogeometry on Peri-Implant Bone Healing: An In Vitro and In Vivo Experimental Study

Background: Primary stability and long-term osseointegration depend on bone healing surrounding dental implants. Implant macrogeometry is crucial for controlling insertion torque and the biological reaction of peri-implant bone. This study assessed the impact of an implant design meant to lessen cortical bone compression on early bone healing. Methods: Forty titanium prototype implants (3 × 6 mm) were equally divided into Control (standard macrogeometry) and Test (macrogeometry with healing chambers) groups. Initial insertion torque was measured in vitro using synthetic bone blocks. Subsequently, an in vivo rabbit tibia model was used (n = 10 implants per group) to assess early healing. At 21 days, histological sections were analyzed for bone-to-implant contact (BIC%) at three cervical positions (C1, C2, and C3). Additionally, digital radiographs of the cervical region were evaluated using RGB color mapping, where distinct color channels quantified varying degrees of bone density. Results: The in vitro insertion torque for the Control group was significantly greater than the Test group (8.01 vs. 5.70 Ncm). The in vivo histomorphometric analysis indicated improved integration for the Test design, showing substantially higher BIC% at the C2 (59.30% vs. 40.30%) and C3 (42.10% vs. 17.90%) positions. Furthermore, radiographic RGB analysis revealed that the Test group possessed a higher blue channel contribution, indicating greater mineralized tissue density. Conclusions: These results imply that modifying implant macrogeometry to lower insertion torque and minimize cortical bone compression favorably enhances early cervical bone healing and osseointegration.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2026-05-01
DOI
https://doi.org/10.3390/jfb17050217
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Reduced Cortical Bone Compression by Implant Macrogeometry on Peri-Implant Bone Healing: An In Vitro and In Vivo Experimental Study

Márcio de Carvalho Formiga, Sergio Rexhep Tari, Sérgio Alexandre Gehrke, Antônio Scarano et al.
Journal of Functional Biomaterials
Dental Implant Techniques and Outcomes
article

Influence of Reduced Cortical Bone Compression by Implant Macrogeometry on Peri-Implant Bone Healing: An In Vitro and In Vivo Experimental Study

Márcio de Carvalho Formiga, Sergio Rexhep Tari, Sérgio Alexandre Gehrke, Antônio Scarano, Gustavo Vicentis Oliveira Fernandes, Tiago Luis Eilers Treichel, Jaime Aramburú Junior, Gustavo Coura, Bruno Freitas Mello
article en

Abstract

Background: Primary stability and long-term osseointegration depend on bone healing surrounding dental implants. Implant macrogeometry is crucial for controlling insertion torque and the biological reaction of peri-implant bone. This study assessed the impact of an implant design meant to lessen cortical bone compression on early bone healing. Methods: Forty titanium prototype implants (3 × 6 mm) were equally divided into Control (standard macrogeometry) and Test (macrogeometry with healing chambers) groups. Initial insertion torque was measured in vitro using synthetic bone blocks. Subsequently, an in vivo rabbit tibia model was used (n = 10 implants per group) to assess early healing. At 21 days, histological sections were analyzed for bone-to-implant contact (BIC%) at three cervical positions (C1, C2, and C3). Additionally, digital radiographs of the cervical region were evaluated using RGB color mapping, where distinct color channels quantified varying degrees of bone density. Results: The in vitro insertion torque for the Control group was significantly greater than the Test group (8.01 vs. 5.70 Ncm). The in vivo histomorphometric analysis indicated improved integration for the Test design, showing substantially higher BIC% at the C2 (59.30% vs. 40.30%) and C3 (42.10% vs. 17.90%) positions. Furthermore, radiographic RGB analysis revealed that the Test group possessed a higher blue channel contribution, indicating greater mineralized tissue density. Conclusions: These results imply that modifying implant macrogeometry to lower insertion torque and minimize cortical bone compression favorably enhances early cervical bone healing and osseointegration.

Journal of Functional BiomaterialsVol. 17(5)
Universidade Católica Portuguesa (PT), Universidade Federal de Santa Maria (BR), University of Chieti-Pescara (IT), Universidad Católica del Uruguay (UY), Universidade de Rio Verde (BR), Missouri Foundation for Health (US), Universidade do Vale do Itajaí (BR), A.T. Still University (US)
Openalex Percentile: Top 6%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.