A Comprehensive Visual Detection Strategy: Versatile LAMP Assay with Phenol Red and Lateral Flow Dipstick for On-Site Detection of Riemerella anatipestifer

Riemerella anatipestifer (RA) is the primary causative agent of infectious serositis in ducks, causing significant economic losses. In this study, a rapid and visual loop-mediated isothermal amplification (LAMP) assay targeting the conserved region of the ompA gene was developed. Specific primers and a FAM-labeled probe were designed, and amplification products were visualized using phenol red-based colorimetric detection and a lateral flow dipstick (LFD) system. Among the five candidate primer sets, primer set 2 was selected because it showed the highest amplification efficiency and specificity, with no cross-reactivity detected against 12 common waterfowl pathogens. Under optimal conditions, the phenol red-based LAMP assay yielded visible results after incubation at 65 °C for 30 min, while the LAMP-LFD assay required an additional 3~5 min probe hybridization step, with detection limits of 7.76 × 102 copies/μL for the phenol red-based method and 7.76 × 100 copies/μL for the LAMP-LFD method. Thirty clinical samples suspected of RA infection were analyzed using conventional PCR and the developed visual LAMP assays. The positive detection rates obtained with the LAMP-LFD and phenol red-based LAMP methods were 63.3% and 60%, respectively, showing high concordance with conventional PCR (56.7%). In conclusion, the LAMP assay integrating phenol red visualization and lateral flow dipstick detection is rapid, sensitive, and easy to perform, and both detection formats show potential for point-of-care or on-site applications, and can be used for the early diagnosis and detection of RA.

Authors

Institutions

Publication Details

Journal
Microorganisms
Published
2026-05-02
DOI
https://doi.org/10.3390/microorganisms14051037
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comprehensive Visual Detection Strategy: Versatile LAMP Assay with Phenol Red and Lateral Flow Dipstick for On-Site Detection of Riemerella anatipestifer

Qiuling Fu, Nansong Jiang, Jiafeng Wu, Yu Huang et al.
Microorganisms
Biosensors and Analytical Detection
article

A Comprehensive Visual Detection Strategy: Versatile LAMP Assay with Phenol Red and Lateral Flow Dipstick for On-Site Detection of Riemerella anatipestifer

Qiuling Fu, Nansong Jiang, Jiafeng Wu, Yu Huang, Rongchang Liu, Tianchao Wei, Chunhe Wan, Weiwei Wang, Hongmei Chen, Longfei Cheng, Guanghua Fu, Qizhang Liang, Ping Wei
article en

Abstract

Riemerella anatipestifer (RA) is the primary causative agent of infectious serositis in ducks, causing significant economic losses. In this study, a rapid and visual loop-mediated isothermal amplification (LAMP) assay targeting the conserved region of the ompA gene was developed. Specific primers and a FAM-labeled probe were designed, and amplification products were visualized using phenol red-based colorimetric detection and a lateral flow dipstick (LFD) system. Among the five candidate primer sets, primer set 2 was selected because it showed the highest amplification efficiency and specificity, with no cross-reactivity detected against 12 common waterfowl pathogens. Under optimal conditions, the phenol red-based LAMP assay yielded visible results after incubation at 65 °C for 30 min, while the LAMP-LFD assay required an additional 3~5 min probe hybridization step, with detection limits of 7.76 × 102 copies/μL for the phenol red-based method and 7.76 × 100 copies/μL for the LAMP-LFD method. Thirty clinical samples suspected of RA infection were analyzed using conventional PCR and the developed visual LAMP assays. The positive detection rates obtained with the LAMP-LFD and phenol red-based LAMP methods were 63.3% and 60%, respectively, showing high concordance with conventional PCR (56.7%). In conclusion, the LAMP assay integrating phenol red visualization and lateral flow dipstick detection is rapid, sensitive, and easy to perform, and both detection formats show potential for point-of-care or on-site applications, and can be used for the early diagnosis and detection of RA.

MicroorganismsVol. 14(5)
Guangxi University (CN), Fujian Academy of Agricultural Sciences (CN)
Natural Science Foundation of Fujian Province, Fujian Academy of Agricultural Sciences
Openalex Percentile: Top 12%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.