Accuracy and Clinical Utility of Spot-Check Noninvasive Hemoglobin Monitoring: A Preliminary Study

INTRODUCTION: Hemoglobin (Hb) monitoring is essential for perioperative management, particularly for detecting anemia and guiding transfusion decisions. Conventional invasive methods provide accurate results but are limited by delays, intermittent sampling, and iatrogenic blood loss. Noninvasive spot-check Hb (SpHb) monitoring offers rapid assessment, but its accuracy is unclear. This study thus evaluated agreement between SpHb obtained with the Rad-67 and invasive Hb measurements in anesthetized patients. METHODS: This single-center, prospective, observational study enrolled 25 adults who underwent gastrointestinal surgery under general anesthesia between June 2023 and March 2024. After induction and stabilization, SpHb was recorded simultaneously with arterial blood sampling. Reference Hb was measured with an automated hematology analyzer (XN-9100), an arterial blood gas analyzer (LC-661), and a portable spectrophotometric device (HemoCue). Correlation was assessed by Pearson's coefficient, and agreement by Bland-Altman analysis. RESULTS: . Mean Hb was 12.6 ± 1.7 g/dL (SpHb), 11.1 ± 1.8 g/dL (XN-9100), 11.4 ± 1.8 g/dL (LC-661), and 11.4 ± 1.8 g/dL (HemoCue). Strong correlations were observed (r = 0.931, 0.930, 0.841; p < 0.001 for all). Bland-Altman analysis showed fixed positive biases of +1.47 g/dL (XN-9100) and +1.19 g/dL (LC-661, HemoCue), without proportional error. CONCLUSIONS: SpHb correlated strongly with invasive Hb but consistently overestimated values by 1-1.5 g/dL. While unsuitable as a direct substitute, SpHb may serve as a bias-aware screening tool that reduces unnecessary phlebotomy.

Authors

Institutions

Publication Details

Journal
Journal of Nippon Medical School
Published
2026-04-20
DOI
https://doi.org/10.1272/jnms.jnms.2026_93-211
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy and Clinical Utility of Spot-Check Noninvasive Hemoglobin Monitoring: A Preliminary Study

Ichiro Kamiya, Chol Kim, Makiko Yamamoto, Yuki Genda et al.
Journal of Nippon Medical School
Clinical Laboratory Practices and Quality Control
article

Accuracy and Clinical Utility of Spot-Check Noninvasive Hemoglobin Monitoring: A Preliminary Study

Ichiro Kamiya, Chol Kim, Makiko Yamamoto, Yuki Genda, Hiroshi Mase, Masashi Ishikawa
article en

Abstract

INTRODUCTION: Hemoglobin (Hb) monitoring is essential for perioperative management, particularly for detecting anemia and guiding transfusion decisions. Conventional invasive methods provide accurate results but are limited by delays, intermittent sampling, and iatrogenic blood loss. Noninvasive spot-check Hb (SpHb) monitoring offers rapid assessment, but its accuracy is unclear. This study thus evaluated agreement between SpHb obtained with the Rad-67 and invasive Hb measurements in anesthetized patients. METHODS: This single-center, prospective, observational study enrolled 25 adults who underwent gastrointestinal surgery under general anesthesia between June 2023 and March 2024. After induction and stabilization, SpHb was recorded simultaneously with arterial blood sampling. Reference Hb was measured with an automated hematology analyzer (XN-9100), an arterial blood gas analyzer (LC-661), and a portable spectrophotometric device (HemoCue). Correlation was assessed by Pearson's coefficient, and agreement by Bland-Altman analysis. RESULTS: . Mean Hb was 12.6 ± 1.7 g/dL (SpHb), 11.1 ± 1.8 g/dL (XN-9100), 11.4 ± 1.8 g/dL (LC-661), and 11.4 ± 1.8 g/dL (HemoCue). Strong correlations were observed (r = 0.931, 0.930, 0.841; p < 0.001 for all). Bland-Altman analysis showed fixed positive biases of +1.47 g/dL (XN-9100) and +1.19 g/dL (LC-661, HemoCue), without proportional error. CONCLUSIONS: SpHb correlated strongly with invasive Hb but consistently overestimated values by 1-1.5 g/dL. While unsuitable as a direct substitute, SpHb may serve as a bias-aware screening tool that reduces unnecessary phlebotomy.

Journal of Nippon Medical SchoolVol. 93(2)
Nippon Medical School Hospital (JP), Chiba Hokusou Hospital (JP), Nippon Medical School (JP)
Zero hunger
Openalex Percentile: Top 9%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies