Atmospheric Cold Microwave Argon Plasma for Decontamination of Dental Implant Surfaces: An In Vitro Experimental Study

Dental implants are widely used to replace missing teeth, but peri-implantitis remains a major biological complication associated with bacterial biofilm formation on implant surfaces. The increasing incidence of peri-implant infections underscores the need for alternative antimicrobial strategies that effectively decontaminate complex titanium implant surfaces. This study evaluated the inhibitory effect of low-temperature microwave argon plasma on bacteria in an experimental model simulating peri-implant conditions and compared the responses of microorganisms with different biological characteristics. A 3D-printed mandibular bone segment model with an inserted Straumann BLX Roxolid® dental implant was used to reproduce the peri-implant environment. Bacterial suspensions of Streptococcus mutans NBIMCC 1786 and the extremophilic bacterium Chromohalobacter canadensis NBIMCC 9077 have been exposed to a microwave non-equilibrium argon plasma jet (2.45 GHz, atmospheric pressure) for 1–7 min. Optical density measurements and colony growth analysis were used to assess antimicrobial effects. Plasma treatment induced a pronounced reduction in bacterial growth during the early post-treatment period. In C. canadensis, growth inhibition reached a plateau (~47–55% at 24 h) regardless of exposure time. In contrast, S. mutans showed a nonlinear response, with stable inhibition after short exposures (1–3 min) and partial recovery after longer treatments (5–7 min). These findings indicate that microwave argon plasma exhibits significant antimicrobial activity under controlled in vitro conditions, although its effectiveness depends on microorganism-specific biological characteristics. Because the present model was based on simplified single-species systems, direct clinical extrapolation remains limited and should be addressed in future studies using polymicrobial peri-implant biofilm models.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2026-05-01
DOI
https://doi.org/10.3390/jfb17050211
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Atmospheric Cold Microwave Argon Plasma for Decontamination of Dental Implant Surfaces: An In Vitro Experimental Study

Nadja Radchenkova, Todor Uzunov, Todor Bogdanov, Raya Grozdanova et al.
Journal of Functional Biomaterials
Plasma Applications and Diagnostics
article

Atmospheric Cold Microwave Argon Plasma for Decontamination of Dental Implant Surfaces: An In Vitro Experimental Study

Nadja Radchenkova, Todor Uzunov, Todor Bogdanov, Raya Grozdanova, Dimitar Kosturkov
article en

Abstract

Dental implants are widely used to replace missing teeth, but peri-implantitis remains a major biological complication associated with bacterial biofilm formation on implant surfaces. The increasing incidence of peri-implant infections underscores the need for alternative antimicrobial strategies that effectively decontaminate complex titanium implant surfaces. This study evaluated the inhibitory effect of low-temperature microwave argon plasma on bacteria in an experimental model simulating peri-implant conditions and compared the responses of microorganisms with different biological characteristics. A 3D-printed mandibular bone segment model with an inserted Straumann BLX Roxolid® dental implant was used to reproduce the peri-implant environment. Bacterial suspensions of Streptococcus mutans NBIMCC 1786 and the extremophilic bacterium Chromohalobacter canadensis NBIMCC 9077 have been exposed to a microwave non-equilibrium argon plasma jet (2.45 GHz, atmospheric pressure) for 1–7 min. Optical density measurements and colony growth analysis were used to assess antimicrobial effects. Plasma treatment induced a pronounced reduction in bacterial growth during the early post-treatment period. In C. canadensis, growth inhibition reached a plateau (~47–55% at 24 h) regardless of exposure time. In contrast, S. mutans showed a nonlinear response, with stable inhibition after short exposures (1–3 min) and partial recovery after longer treatments (5–7 min). These findings indicate that microwave argon plasma exhibits significant antimicrobial activity under controlled in vitro conditions, although its effectiveness depends on microorganism-specific biological characteristics. Because the present model was based on simplified single-species systems, direct clinical extrapolation remains limited and should be addressed in future studies using polymicrobial peri-implant biofilm models.

Journal of Functional BiomaterialsVol. 17(5)
Medical University of Sofia (BG), Stephan Angeloff Institute of Microbiology (BG)
European Commission
Openalex Percentile: Top 7%
Plasma Applications and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.