Real-Time Cognitive Load Measurement of Pupillary Oscillation

A comprehensive signal-analytic examination is made of the detection of cognitive load from the measurement of pupil diameter oscillation. Earlier such computational methods failed to provide a real-time variant of frequency-based approaches and failed to justify various design choices. In this work, the problem is approached from first principles, considering what pupillary oscillations should be expected, both under rest and under (cognitive) load. Then three detection techniques are derived based on the Fast Fourier Transform (FFT), the Discrete Wavelet Transform (DWT), and the Butterworth filter to compute the Low/High Frequency (LF/HF) ratio. The work also covers the minimum signal duration required for each method, the theoretical range of the LF/HF ratio, drawing from physiological and signal processing perspectives, and the minimum time window needed to produce output. It is shown that the Butterworth filter is better suited for real-time implementation than the other two.

Authors

Institutions

Publication Details

Journal
Proceedings of the ACM on Computer Graphics and Interactive Techniques
Published
2026-05-01
DOI
https://doi.org/10.1145/3803537
Primary Topic
Tactile and Sensory Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Cognitive Load Measurement of Pupillary Oscillation

Andrew Duchowski
Proceedings of the ACM on Computer Graphics and Interactive Techniques
Tactile and Sensory Interactions
article

Real-Time Cognitive Load Measurement of Pupillary Oscillation

Andrew Duchowski
article en

Abstract

A comprehensive signal-analytic examination is made of the detection of cognitive load from the measurement of pupil diameter oscillation. Earlier such computational methods failed to provide a real-time variant of frequency-based approaches and failed to justify various design choices. In this work, the problem is approached from first principles, considering what pupillary oscillations should be expected, both under rest and under (cognitive) load. Then three detection techniques are derived based on the Fast Fourier Transform (FFT), the Discrete Wavelet Transform (DWT), and the Butterworth filter to compute the Low/High Frequency (LF/HF) ratio. The work also covers the minimum signal duration required for each method, the theoretical range of the LF/HF ratio, drawing from physiological and signal processing perspectives, and the minimum time window needed to produce output. It is shown that the Butterworth filter is better suited for real-time implementation than the other two.

Proceedings of the ACM on Computer Graphics and Interactive TechniquesVol. 9(2)
Clemson University (US)
Openalex Percentile: Top 7%
Tactile and Sensory Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Real-Time Cognitive Load Measurement of Pupillary Oscillation — Andrew Duchowski · Proceedings of the ACM on Computer Graphics and Interactive Techniques (2026) | TGRS Research Map | TGRS