Automated Measurement of Occipito-Axial Angle on Cervical Radiographs Using a Deep Learning Object Detection Model: A Proof-of-Concept Study

Objective: Maintaining the occipito-axial (O-C2) angle following occipitocervical fusion is crucial to prevent postoperative complications. Although automated O-C2 measurement has been reported, practical methods that provide rapid results for routine practice remain limited. This study aimed to develop a deep learning model using the YOLO (You Only Look Once) object detection algorithm to automatically identify anatomical landmarks and rapidly calculate the O-C2 angle. Methods: A retrospective analysis was conducted using cervical spine radiographs from 2 independent facilities. The internal dataset comprised 574 lateral cervical radiographs from 271 patients for model development, while the external validation dataset included 100 radiographs from 100 patients. Model performance was evaluated against manual measurements by 3 expert raters. Results: The model demonstrated excellent detection performance, achieving perfect metrics for the hard palate (F1 score: 1.00) and high performance for the occipital bone (F1 score: 0.97), anteroinferior corner of C2 (F1 score: 0.99), and posteroinferior corner of C2 (F1 score: 0.99). For O-C2 angle estimation, the mean absolute error was 2.35° and root mean squared error was 2.98°, with an accuracy of 94.7% for determining the presence or absence of the O-C2 angle (i.e., whether all 4 anatomical landmarks were simultaneously detected). Bland-Altman analysis revealed minimal bias (0.57°; 95% confidence interval, -0.06° to 1.12°) with limits of agreement from -5.19° to 6.33°. Inference time was approximately 0.14 s per image. Conclusion: Our deep learning model enables rapid and accurate O-C2 angle measurement on lateral cervical radiographs, demonstrating performance comparable to expert raters and potential clinical utility.

Authors

Institutions

Publication Details

Journal
Neurospine
Published
2026-04-29
DOI
https://doi.org/10.14245/ns.2551878.939
Primary Topic
Cervical and Thoracic Myelopathy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated Measurement of Occipito-Axial Angle on Cervical Radiographs Using a Deep Learning Object Detection Model: A Proof-of-Concept Study

Yutaro Fuse, Takashi Abe, Yoshitaka Nagashima, Shun Yamamoto et al.
Neurospine
Cervical and Thoracic Myelopathy
article

Automated Measurement of Occipito-Axial Angle on Cervical Radiographs Using a Deep Learning Object Detection Model: A Proof-of-Concept Study

Yutaro Fuse, Takashi Abe, Yoshitaka Nagashima, Shun Yamamoto, Nobuhiro Hata, T. Gonda, Kensaku Mori, Ryuta Saito, Mamoru Matsuo, Yusuke Nishimura
article en

Abstract

Objective: Maintaining the occipito-axial (O-C2) angle following occipitocervical fusion is crucial to prevent postoperative complications. Although automated O-C2 measurement has been reported, practical methods that provide rapid results for routine practice remain limited. This study aimed to develop a deep learning model using the YOLO (You Only Look Once) object detection algorithm to automatically identify anatomical landmarks and rapidly calculate the O-C2 angle. Methods: A retrospective analysis was conducted using cervical spine radiographs from 2 independent facilities. The internal dataset comprised 574 lateral cervical radiographs from 271 patients for model development, while the external validation dataset included 100 radiographs from 100 patients. Model performance was evaluated against manual measurements by 3 expert raters. Results: The model demonstrated excellent detection performance, achieving perfect metrics for the hard palate (F1 score: 1.00) and high performance for the occipital bone (F1 score: 0.97), anteroinferior corner of C2 (F1 score: 0.99), and posteroinferior corner of C2 (F1 score: 0.99). For O-C2 angle estimation, the mean absolute error was 2.35° and root mean squared error was 2.98°, with an accuracy of 94.7% for determining the presence or absence of the O-C2 angle (i.e., whether all 4 anatomical landmarks were simultaneously detected). Bland-Altman analysis revealed minimal bias (0.57°; 95% confidence interval, -0.06° to 1.12°) with limits of agreement from -5.19° to 6.33°. Inference time was approximately 0.14 s per image. Conclusion: Our deep learning model enables rapid and accurate O-C2 angle measurement on lateral cervical radiographs, demonstrating performance comparable to expert raters and potential clinical utility.

NeurospineVol. 23(2)
Berurando General Hospital (JP), Nagoya University (JP)
Aichi Health Promotion Foundation, Ministry of Education, Culture, Sports, Science and Technology, Japan Science and Technology Agency
Openalex Percentile: Top 13%
Cervical and Thoracic Myelopathy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.