Combined Snare and Buddy-Balloon Strategy for Failed Valve Crossing in Valve-in-Valve Transcatheter Aortic Valve Replacement
BACKGROUND: Retrograde valve crossing during valve-in-valve transcatheter aortic valve replacement (ViV TAVR) may fail despite modern delivery systems. CASE SUMMARY: A 67-year-old man with a degenerated 27-mm Magna Ease bioprosthesis and unfavorable aortic geometry (kinked ascending aorta at a prior surgical graft site) underwent ViV TAVR, where retrograde valve crossing failed despite multiple stiff guidewires and snare traction alone. Successful delivery of a 29-mm Evolut FX+ was ultimately achieved by combining gooseneck-snare traction for coaxial realignment with a partially inflated Tyshak buddy balloon acting as a mechanical ramp across the surgical valve frame. DISCUSSION: This case demonstrates a structured, stepwise approach to managing failed valve crossing in ViV TAVR, highlighting the mechanical roles of snare traction and balloon-mediated coaxial alignment. TAKE-HOME MESSAGE: A combined snare and buddy-balloon strategy can facilitate valve delivery when conventional retrograde crossing fails during ViV TAVR.
Authors
- Joshua A. Cohen (ORCID: https://orcid.org/0000-0002-7211-7676)
- Matthew Summers (ORCID: https://orcid.org/0000-0001-5327-5815)
- Raymond L. Benza (ORCID: https://orcid.org/0000-0001-9627-6236)
- Deepak R Talreja
- Hira Sarfraz (ORCID: https://orcid.org/0009-0000-4503-1810)
- Muhammad U. Javed
- Parth K. Parikh
Institutions
- Sentara Norfolk General Hospital (US)
- Eastern Virginia Medical School (US)
- Riverside Regional Medical Center (US)
- Sentara Virginia Beach General Hospital (US)
- Old Dominion University (US)
Publication Details
- Journal
- JACC Case Reports
- Published
- 2026-05-01
- DOI
- https://doi.org/10.1016/j.jaccas.2026.108048
- Primary Topic
- Cardiac Valve Diseases and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00