Broadband Micro-Confocal Raman Spectrometer Using Four Tiled Sub-Gratings and Optimized Cylindrical Lens Correction

A micro-confocal Raman spectrometer is developed using four tiled sub-gratings, each with a groove density of 1200 lines/mm, and a single optimized cylindrical lens. The system achieves a broad Raman shift coverage from 99.8 to 4701 cm−1 with a spectral resolution of approximately 4 cm−1, and operates without any mechanical moving parts. The cylindrical lens corrects multi-channel astigmatism, compressing the spot size to one quarter of its original dimension and improving the signal-to-noise ratio by a factor of four. The prototype successfully detects Raman signals from silicon, sodium nitrite, cyclohexane, and sodium sulfate solutions with concentrations as low as 0.01 mol/L. It also resolves inorganic mixtures, minerals including celestine, rhodonite, and calcite, as well as microplastics such as polyamide, polytetrafluoroethylene, polyethylene, and styrene-ethylene-butylene-styrene block copolymer. These results demonstrate that the spectrometer offers reliable qualitative and quantitative detection capabilities with both broad spectral bandwidth and high resolution.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-04-30
DOI
https://doi.org/10.3390/app16094384
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Broadband Micro-Confocal Raman Spectrometer Using Four Tiled Sub-Gratings and Optimized Cylindrical Lens Correction

Shuo Yu, Heshig Bayan, Guangdong Yu, Y W Sun et al.
Applied Sciences
Spectroscopy Techniques in Biomedical and Chemical Research
article

Broadband Micro-Confocal Raman Spectrometer Using Four Tiled Sub-Gratings and Optimized Cylindrical Lens Correction

Shuo Yu, Heshig Bayan, Guangdong Yu, Y W Sun, Wei Bai, Geng Wang, Xiaotian Li, Galantu Jiri, Ci Sun
article en

Abstract

A micro-confocal Raman spectrometer is developed using four tiled sub-gratings, each with a groove density of 1200 lines/mm, and a single optimized cylindrical lens. The system achieves a broad Raman shift coverage from 99.8 to 4701 cm−1 with a spectral resolution of approximately 4 cm−1, and operates without any mechanical moving parts. The cylindrical lens corrects multi-channel astigmatism, compressing the spot size to one quarter of its original dimension and improving the signal-to-noise ratio by a factor of four. The prototype successfully detects Raman signals from silicon, sodium nitrite, cyclohexane, and sodium sulfate solutions with concentrations as low as 0.01 mol/L. It also resolves inorganic mixtures, minerals including celestine, rhodonite, and calcite, as well as microplastics such as polyamide, polytetrafluoroethylene, polyethylene, and styrene-ethylene-butylene-styrene block copolymer. These results demonstrate that the spectrometer offers reliable qualitative and quantitative detection capabilities with both broad spectral bandwidth and high resolution.

Applied SciencesVol. 16(9)
Chinese Academy of Sciences (CN), Changchun Institute of Optics, Fine Mechanics and Physics (CN), International Centre for Diffraction Data (US), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 7%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.