Evaluation Method of Water Absorption Profile Based on Temperature Profile of Water Injection Well

Distributed fiber optic temperature sensing (DTS) monitoring technology is increasingly widely applied in oil reservoir water injection development. However, existing DTS interpretation methods for layered water injection processes have insufficiently considered the effects of multilayer injection and reservoir damage. To address this issue, this paper takes into account interlayer heterogeneity and reservoir damage and, based on the laws of conservation of mass and energy, comprehensively incorporates the effects of friction, the Joule–Thomson effect, thermal convection, and thermal expansion. By coupling wellbore pipe flow with formation seepage, a temperature profile prediction model for multilayer water absorption under steady-state water injection conditions is established. Comparative validation against classical models such as those by Babak and Nowak demonstrates that the proposed model achieves high computational accuracy. Using this model, the influence patterns of injection rate, tubing diameter, formation coefficient, and skin factor on wellbore temperature distribution are systematically analyzed: a higher injection rate leads to a smaller temperature rise in the injected water; a larger tubing diameter results in a greater temperature rise; the formation coefficient affects the temperature profile by regulating interlayer water absorption distribution, while reservoir damage (skin factor) has a relatively limited direct impact on the temperature profile. The model is applied to interpret DTS field data from Well A, and the water absorption rate of each sublayer is quantitatively obtained: the main water absorbing intervals are 1878.7–1897.5 m and 1919.5–1950.6 m, with water absorption accounting for 30.57% and 24.28% of the total injection rate, respectively, while the remaining intervals exhibit secondary water absorption. These interpretation results are in good agreement with earlier oxygen activation tests. This study provides a theoretical basis and analytical method for applying distributed fiber optic temperature measurement technology to monitor water absorption profiles in multilayer injection wells.

Authors

Institutions

Publication Details

Journal
Eng—Advances in Engineering
Published
2026-05-01
DOI
https://doi.org/10.3390/eng7050213
Primary Topic
Hydraulic Fracturing and Reservoir Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation Method of Water Absorption Profile Based on Temperature Profile of Water Injection Well

Chen Peng, Zheng Yuhui, Yang Wei, Wang Kun et al.
Eng—Advances in Engineering
Hydraulic Fracturing and Reservoir Analysis
article

Evaluation Method of Water Absorption Profile Based on Temperature Profile of Water Injection Well

Chen Peng, Zheng Yuhui, Yang Wei, Wang Kun, Zhang Tao
article en

Abstract

Distributed fiber optic temperature sensing (DTS) monitoring technology is increasingly widely applied in oil reservoir water injection development. However, existing DTS interpretation methods for layered water injection processes have insufficiently considered the effects of multilayer injection and reservoir damage. To address this issue, this paper takes into account interlayer heterogeneity and reservoir damage and, based on the laws of conservation of mass and energy, comprehensively incorporates the effects of friction, the Joule–Thomson effect, thermal convection, and thermal expansion. By coupling wellbore pipe flow with formation seepage, a temperature profile prediction model for multilayer water absorption under steady-state water injection conditions is established. Comparative validation against classical models such as those by Babak and Nowak demonstrates that the proposed model achieves high computational accuracy. Using this model, the influence patterns of injection rate, tubing diameter, formation coefficient, and skin factor on wellbore temperature distribution are systematically analyzed: a higher injection rate leads to a smaller temperature rise in the injected water; a larger tubing diameter results in a greater temperature rise; the formation coefficient affects the temperature profile by regulating interlayer water absorption distribution, while reservoir damage (skin factor) has a relatively limited direct impact on the temperature profile. The model is applied to interpret DTS field data from Well A, and the water absorption rate of each sublayer is quantitatively obtained: the main water absorbing intervals are 1878.7–1897.5 m and 1919.5–1950.6 m, with water absorption accounting for 30.57% and 24.28% of the total injection rate, respectively, while the remaining intervals exhibit secondary water absorption. These interpretation results are in good agreement with earlier oxygen activation tests. This study provides a theoretical basis and analytical method for applying distributed fiber optic temperature measurement technology to monitor water absorption profiles in multilayer injection wells.

Eng—Advances in EngineeringVol. 7(5)
Yangtze University (CN), Hainan University (CN), Zhanjiang Experimental Station (CN)
Clean water and sanitation
Openalex Percentile: Top 11%
Hydraulic Fracturing and Reservoir Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.