Concurrent phakic intraocular lens explantation and phacoemulsification with IOL implantation: A retrospective analysis of efficacy and safety

PURPOSE: To evaluate the efficacy and safety of cataract surgery in patients who underwent posterior chamber phakic intraocular lens (PCpIOL) explantation combined with phacoemulsification and intraocular lens (IOL) implantation, with a minimum follow-up period of 2 years postoperatively. Methods: Retrospective study done at a tertiary eye care hospital in South India. STUDY POPULATION: Electronic medical records of 57 eyes of patients who underwent PCpIOL explantation combined with phacoemulsification and IOL implantation due to cataract development between 2009 and 2022 were analyzed for visual outcomes, IOL power predictability, and intraoperative or postoperative complications. INTERVENTION: Phacoemulsification was performed in 54 eyes, and femtosecond laser-assisted cataract surgery (FLACS) was performed in three eyes. MAIN OUTCOME MEASURE: Efficacy and safety of cataract surgery in these patients. RESULTS: Anterior subcapsular cataract development remains the most common cause for pIOL explantation. The phakic IOL models explanted in our study were implantable collamer lens (ICL) V4b, implantable phakic contact lens (IPCL) V1, and IPCL V2. Good improvement in corrected distance visual acuity (CDVA) was observed post-phacoemulsification, with 80.6% achieving CDVA of 0.3 logMAR or better. A total of 86.1% of the eyes were within +/-1.00 D of the target refraction (spherical equivalent). No intraoperative or early postoperative complications were noted. Posterior capsular opacification developed in 11 eyes, and retinal detachment (RD) in one eye. CONCLUSION: Phacoemulsification post-PCpIOL explantation yields good visual outcomes, a high safety profile, and stable refraction, without increased complications. The Barrett Suite formula reliably predicts IOL power calculation. A detailed preoperative fundus examination, with emphasis on the peripheral retina, is vital prior to PCpIOL implantation and phacoemulsification.

Authors

Institutions

Publication Details

Journal
Indian Journal of Ophthalmology
Published
2026-04-30
DOI
https://doi.org/10.4103/ijo.ijo_1718_25
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Concurrent phakic intraocular lens explantation and phacoemulsification with IOL implantation: A retrospective analysis of efficacy and safety

Ramamurthy Dandapani, Gitansha Sachdev, T Zunaitha Fathima, S Tamilarasi
Indian Journal of Ophthalmology
Corneal surgery and disorders
article

Concurrent phakic intraocular lens explantation and phacoemulsification with IOL implantation: A retrospective analysis of efficacy and safety

Ramamurthy Dandapani, Gitansha Sachdev, T Zunaitha Fathima, S Tamilarasi
article en

Abstract

PURPOSE: To evaluate the efficacy and safety of cataract surgery in patients who underwent posterior chamber phakic intraocular lens (PCpIOL) explantation combined with phacoemulsification and intraocular lens (IOL) implantation, with a minimum follow-up period of 2 years postoperatively. Methods: Retrospective study done at a tertiary eye care hospital in South India. STUDY POPULATION: Electronic medical records of 57 eyes of patients who underwent PCpIOL explantation combined with phacoemulsification and IOL implantation due to cataract development between 2009 and 2022 were analyzed for visual outcomes, IOL power predictability, and intraoperative or postoperative complications. INTERVENTION: Phacoemulsification was performed in 54 eyes, and femtosecond laser-assisted cataract surgery (FLACS) was performed in three eyes. MAIN OUTCOME MEASURE: Efficacy and safety of cataract surgery in these patients. RESULTS: Anterior subcapsular cataract development remains the most common cause for pIOL explantation. The phakic IOL models explanted in our study were implantable collamer lens (ICL) V4b, implantable phakic contact lens (IPCL) V1, and IPCL V2. Good improvement in corrected distance visual acuity (CDVA) was observed post-phacoemulsification, with 80.6% achieving CDVA of 0.3 logMAR or better. A total of 86.1% of the eyes were within +/-1.00 D of the target refraction (spherical equivalent). No intraoperative or early postoperative complications were noted. Posterior capsular opacification developed in 11 eyes, and retinal detachment (RD) in one eye. CONCLUSION: Phacoemulsification post-PCpIOL explantation yields good visual outcomes, a high safety profile, and stable refraction, without increased complications. The Barrett Suite formula reliably predicts IOL power calculation. A detailed preoperative fundus examination, with emphasis on the peripheral retina, is vital prior to PCpIOL implantation and phacoemulsification.

Indian Journal of OphthalmologyVol. 74(Suppl 1)
Aravind Eye Hospital (IN), Orthopaedic Research Group (IN)
Good health and well-being
Openalex Percentile: Top 10%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.