Clinical, Physiologic, and Anatomic Outcomes of a Novel Bioprosthetic Aortic Valved Conduit

Background: In 2020, the first pre-assembled bioprosthetic aortic valved conduit (AVC) was approved in the United States. This study compares its anatomic and functional outcomes to traditional hand-sewn composite conduits in patients undergoing aortic root replacement. Methods: This retrospective study compared 118 patients receiving the pre-assembled AVC (2021–2023) versus 66 patients with hand-sewn conduits (2012–2020) after elective bio-Bentall procedures. Primary outcomes were post-operative mortality and complication rates. Secondary outcomes included anatomic and hemodynamic changes. Graft dimensions were obtained from post-operative computed tomography (CT). Echocardiographic parameters were collected at early and late follow-up. Between-group differences and longitudinal changes were assessed using linear mixed-effects models. Results: Groups were comparable in age (pre-assembled 63 ± 11 vs. hand-sewn 64 ± 11 years) and predominantly male. Despite significantly higher concomitant hemiarch rates in pre-assembled conduits (91.5% vs. 28.8%, p < 0.001), 30-day mortality, stroke, and reoperation for bleeding were comparable between groups. Pre-assembled conduits demonstrated superior hemodynamics with lower baseline peak gradients (Δ 9.1 mmHg, p < 0.001), lower mean gradients (Δ 5.3 mmHg, p < 0.001), and larger indexed effective orifice area (Δ 0.27 cm2/m2, p = 0.018). Annual rates of hemodynamic and dimensional change were minimal and comparable between groups. Kaplan–Meier analysis showed no survival difference at 3 years. Conclusions: The pre-assembled AVC demonstrates equivalent safety and superior early hemodynamic performance compared to hand-sewn conduits, with stable mid-term anatomic and functional outcomes.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-04-30
DOI
https://doi.org/10.3390/jcm15093437
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical, Physiologic, and Anatomic Outcomes of a Novel Bioprosthetic Aortic Valved Conduit

Sriharsha Talapaneni, Roland Assi, Sem Asmelash, Prashanth Vallabhajosyula et al.
Journal of Clinical Medicine
Aortic Disease and Treatment Approaches
article

Clinical, Physiologic, and Anatomic Outcomes of a Novel Bioprosthetic Aortic Valved Conduit

Sriharsha Talapaneni, Roland Assi, Sem Asmelash, Prashanth Vallabhajosyula, Kristina Wang, Titilayo Oden Shobayo, K. Ofori, Adrian R Acuna Higaki, Sedem Dankwa, Pavan Khosla, Shiv Verma, Irbaz Hameed, Ely Erez
article en

Abstract

Background: In 2020, the first pre-assembled bioprosthetic aortic valved conduit (AVC) was approved in the United States. This study compares its anatomic and functional outcomes to traditional hand-sewn composite conduits in patients undergoing aortic root replacement. Methods: This retrospective study compared 118 patients receiving the pre-assembled AVC (2021–2023) versus 66 patients with hand-sewn conduits (2012–2020) after elective bio-Bentall procedures. Primary outcomes were post-operative mortality and complication rates. Secondary outcomes included anatomic and hemodynamic changes. Graft dimensions were obtained from post-operative computed tomography (CT). Echocardiographic parameters were collected at early and late follow-up. Between-group differences and longitudinal changes were assessed using linear mixed-effects models. Results: Groups were comparable in age (pre-assembled 63 ± 11 vs. hand-sewn 64 ± 11 years) and predominantly male. Despite significantly higher concomitant hemiarch rates in pre-assembled conduits (91.5% vs. 28.8%, p < 0.001), 30-day mortality, stroke, and reoperation for bleeding were comparable between groups. Pre-assembled conduits demonstrated superior hemodynamics with lower baseline peak gradients (Δ 9.1 mmHg, p < 0.001), lower mean gradients (Δ 5.3 mmHg, p < 0.001), and larger indexed effective orifice area (Δ 0.27 cm2/m2, p = 0.018). Annual rates of hemodynamic and dimensional change were minimal and comparable between groups. Kaplan–Meier analysis showed no survival difference at 3 years. Conclusions: The pre-assembled AVC demonstrates equivalent safety and superior early hemodynamic performance compared to hand-sewn conduits, with stable mid-term anatomic and functional outcomes.

Journal of Clinical MedicineVol. 15(9)
Yale University (US)
Good health and well-being
Openalex Percentile: Top 9%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.