Admissible Reconstruction of Reaction-Channel Levels on Fixed Subgroup Support and Probabilities in Algebraic Probability Table Construction

This work considers admissibility-enforcing reconstruction of reaction-channel subgroup levels on prescribed total-subgroup support and probabilities, a setting in which conventional exact reconstruction may produce negative reaction-channel levels. The proposed reconstruction relaxes conventional full matching by retaining selected low-order channel quantities associated with limiting dilution responses exactly, while fitting the remaining matching conditions in a constrained least-squares sense under nonnegativity. The exact-retention constraints are embedded through a null-space parametrization, which reduces the reconstruction to a convex optimization problem over the remaining degrees of freedom. Two variants are examined: a single-retention formulation, which is automatically feasible for nonnegative retained data, and a two-retention formulation, which is more restrictive and depends on compatibility with the fixed total-subgroup rule. Numerical tests for 238U capture data show that the proposed reconstruction removes the negative reaction-channel levels observed in the violating groups. Restoring admissibility entails deterioration in response accuracy relative to the unconstrained full-matching baseline, reflecting the trade-off between exact matching and nonnegativity on the fixed rule. Of the two variants considered, the single-retention formulation shows more stable overall behavior in the present comparison. In particular, for all violating cases at orders N≥10, it restores nonnegativity, with the reported 95th-percentile relative errors in the folded effective cross section not exceeding 8.90×10−7.

Authors

Institutions

Publication Details

Journal
Computation
Published
2026-04-30
DOI
https://doi.org/10.3390/computation14050103
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Admissible Reconstruction of Reaction-Channel Levels on Fixed Subgroup Support and Probabilities in Algebraic Probability Table Construction

Beichen Zheng, Lili Wen
Computation
Medical Imaging Techniques and Applications
article

Admissible Reconstruction of Reaction-Channel Levels on Fixed Subgroup Support and Probabilities in Algebraic Probability Table Construction

Beichen Zheng, Lili Wen
article en

Abstract

This work considers admissibility-enforcing reconstruction of reaction-channel subgroup levels on prescribed total-subgroup support and probabilities, a setting in which conventional exact reconstruction may produce negative reaction-channel levels. The proposed reconstruction relaxes conventional full matching by retaining selected low-order channel quantities associated with limiting dilution responses exactly, while fitting the remaining matching conditions in a constrained least-squares sense under nonnegativity. The exact-retention constraints are embedded through a null-space parametrization, which reduces the reconstruction to a convex optimization problem over the remaining degrees of freedom. Two variants are examined: a single-retention formulation, which is automatically feasible for nonnegative retained data, and a two-retention formulation, which is more restrictive and depends on compatibility with the fixed total-subgroup rule. Numerical tests for 238U capture data show that the proposed reconstruction removes the negative reaction-channel levels observed in the violating groups. Restoring admissibility entails deterioration in response accuracy relative to the unconstrained full-matching baseline, reflecting the trade-off between exact matching and nonnegativity on the fixed rule. Of the two variants considered, the single-retention formulation shows more stable overall behavior in the present comparison. In particular, for all violating cases at orders N≥10, it restores nonnegativity, with the reported 95th-percentile relative errors in the folded effective cross section not exceeding 8.90×10−7.

ComputationVol. 14(5)
China Institute of Atomic Energy (CN)
Peace, Justice and strong institutions
Openalex Percentile: Top 7%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.