Box–Behnken Design Optimized LC‐MS/MS Method for Sensitive and Rapid Determination of Baricitinib in Biological Matrix

ABSTRACT A highly sensitive and robust LC–MS/MS method was developed and validated for the quantification of baricitinib in human plasma, employing ruxolitinib as an internal standard (IS). Sample preparation involved simple protein precipitation, and chromatographic separation was achieved on a Luna C18 column (50 × 2.0 mm, 3 µm) using an isocratic mobile phase consisting of 0.1% formic acid in water and acetonitrile (50:50, v/v). Key mass spectrometric parameters—including capillary voltage (3.75 kV), cone voltage (20 V), and collision energy (32 eV)—were systematically optimized using a Box–Behnken design (BBD), ensuring maximum sensitivity and reproducibility. The method exhibited excellent linearity over the concentration range of 1–200 ng/mL (R 2 = 0.99993), with intra‐ and inter‐day precision (%RSD ≤ 4.95%) and accuracy (92.00%–99.06%) within acceptable limits as per FDA and EMA bioanalytical method validation guidelines. The extraction recovery of baricitinib was high and consistent (95.73%–97.38%), while matrix effects were minimal (IS‐normalized matrix factor: 1.067–1.136, %RSD < 5%). Stability studies confirmed that baricitinib remained stable under various storage and processing conditions, including freeze–thaw, short‐term, long‐term, and benchtop stability. The validated method demonstrates its suitability for therapeutic drug monitoring of baricitinib in clinical settings, including treatment of rheumatoid arthritis, pediatric autoinflammatory conditions, and investigational oncology applications.

Authors

Institutions

Publication Details

Journal
Separation Science Plus
Published
2026-05-01
DOI
https://doi.org/10.1002/sscp.70238
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Box–Behnken Design Optimized LC‐MS/MS Method for Sensitive and Rapid Determination of Baricitinib in Biological Matrix

Hemambika Sadasivuni, Shashipal Aitha, Devaraju Subramani, Kiran Kumar Tatapudi et al.
Separation Science Plus
Analytical Methods in Pharmaceuticals
article

Box–Behnken Design Optimized LC‐MS/MS Method for Sensitive and Rapid Determination of Baricitinib in Biological Matrix

Hemambika Sadasivuni, Shashipal Aitha, Devaraju Subramani, Kiran Kumar Tatapudi, Tiruveedhula Somasekhar
article en

Abstract

ABSTRACT A highly sensitive and robust LC–MS/MS method was developed and validated for the quantification of baricitinib in human plasma, employing ruxolitinib as an internal standard (IS). Sample preparation involved simple protein precipitation, and chromatographic separation was achieved on a Luna C18 column (50 × 2.0 mm, 3 µm) using an isocratic mobile phase consisting of 0.1% formic acid in water and acetonitrile (50:50, v/v). Key mass spectrometric parameters—including capillary voltage (3.75 kV), cone voltage (20 V), and collision energy (32 eV)—were systematically optimized using a Box–Behnken design (BBD), ensuring maximum sensitivity and reproducibility. The method exhibited excellent linearity over the concentration range of 1–200 ng/mL (R 2 = 0.99993), with intra‐ and inter‐day precision (%RSD ≤ 4.95%) and accuracy (92.00%–99.06%) within acceptable limits as per FDA and EMA bioanalytical method validation guidelines. The extraction recovery of baricitinib was high and consistent (95.73%–97.38%), while matrix effects were minimal (IS‐normalized matrix factor: 1.067–1.136, %RSD < 5%). Stability studies confirmed that baricitinib remained stable under various storage and processing conditions, including freeze–thaw, short‐term, long‐term, and benchtop stability. The validated method demonstrates its suitability for therapeutic drug monitoring of baricitinib in clinical settings, including treatment of rheumatoid arthritis, pediatric autoinflammatory conditions, and investigational oncology applications.

Separation Science PlusVol. 9(5)
Vignan's Foundation for Science, Technology & Research (IN), Administrative Staff College of India (IN), Vignana Jyothi Institute of Management (IN), Suven Life Sciences (India) (IN), PSG INSTITUTE OF TECHNOLOGY AND APPLIED RESEARCH (IN)
Clean water and sanitation
Openalex Percentile: Top 10%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Box–Behnken Design Optimized LC‐MS/MS Method for Sensitive and Rapid Determination of Baricitinib in Biological Matrix — Hemambika Sadasivuni, Shashipal Aitha, et al. · Separation Science Plus (2026) | TGRS Research Map | TGRS