Calculating the space-charge-limited current density for nonplanar geometries by simulating the charge-free electric field

Calculating the space-charge-limited-current density (SCLCD) for a complicated diode geometry often requires computationally expensive particle-in-cell (PIC) codes. This paper addresses this issue by using the charge-free electric field E0 calculated using COMSOL Multiphysics to determine local and global SCLCD. The SCLCD obtained by using the surface average of E02 on the cathode recovers theoretical results for one-dimensional (1D) planar, cylindrical, and tip-to-tip geometries in appropriate limits. We next compared tip-to-tip calculations with the SCLCD obtained using the PIC code Empire. The SCLCD calculated using COMSOL agreed well with Empire for flatter 1D tip-to-tip geometries and diverged with increasing sharpness. Physically, Empire predicts lower SCLCD than COMSOL because the electrons spread due to concentrated space-charge at the tip, whereas theory assumes that the electrons follow the charge-free electric field lines. We further assess the behavior of the SCLCD for tips protruding from the centers of flat, circular plates of various areas. Larger plate areas with constant tip size recover the 1D planar SCLCD globally and 1D tip-to-tip SCLCD locally, while reducing the difference between Empire and COMSOL calculations since larger plates capture more of the emitted electrons, reducing SCLCD suppression due to beam spreading. These results show that charge-free electric field simulations can be used to determine the SCLCD without needing to simulate particle dynamics in PIC.

Authors

Institutions

Publication Details

Journal
Physics of Plasmas
Published
2026-05-01
DOI
https://doi.org/10.1063/5.0326800
Primary Topic
Gyrotron and Vacuum Electronics Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calculating the space-charge-limited current density for nonplanar geometries by simulating the charge-free electric field

Allen L. Garner, J. K. Wright, Carter Eckardt, Adam M. Darr
Physics of Plasmas
Gyrotron and Vacuum Electronics Research
article

Calculating the space-charge-limited current density for nonplanar geometries by simulating the charge-free electric field

Allen L. Garner, J. K. Wright, Carter Eckardt, Adam M. Darr
article en

Abstract

Calculating the space-charge-limited-current density (SCLCD) for a complicated diode geometry often requires computationally expensive particle-in-cell (PIC) codes. This paper addresses this issue by using the charge-free electric field E0 calculated using COMSOL Multiphysics to determine local and global SCLCD. The SCLCD obtained by using the surface average of E02 on the cathode recovers theoretical results for one-dimensional (1D) planar, cylindrical, and tip-to-tip geometries in appropriate limits. We next compared tip-to-tip calculations with the SCLCD obtained using the PIC code Empire. The SCLCD calculated using COMSOL agreed well with Empire for flatter 1D tip-to-tip geometries and diverged with increasing sharpness. Physically, Empire predicts lower SCLCD than COMSOL because the electrons spread due to concentrated space-charge at the tip, whereas theory assumes that the electrons follow the charge-free electric field lines. We further assess the behavior of the SCLCD for tips protruding from the centers of flat, circular plates of various areas. Larger plate areas with constant tip size recover the 1D planar SCLCD globally and 1D tip-to-tip SCLCD locally, while reducing the difference between Empire and COMSOL calculations since larger plates capture more of the emitted electrons, reducing SCLCD suppression due to beam spreading. These results show that charge-free electric field simulations can be used to determine the SCLCD without needing to simulate particle dynamics in PIC.

Physics of PlasmasVol. 33(5)
Purdue University West Lafayette (US), Sandia National Laboratories (US)
Air Force Office of Scientific Research, Sandia National Laboratories
Openalex Percentile: Top 7%
Gyrotron and Vacuum Electronics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.