Establishing Local Diagnostic Reference Levels (DRLs) for Adult Computed Tomography in Emirates Health Services Hospitals: A Multicenter Dose Survey

Objectives: This study aimed to establish local Diagnostic Reference Levels (DRLs) for adult computed tomography (CT) across Emirates Health Services (EHS) hospitals in the United Arab Emirates. Methods: A retrospective multicenter survey included 1257 adult patients from seven EHS hospitals who underwent six routine CT protocols: head without contrast (n = 375), chest without contrast (n = 403), chest with contrast (n = 50), abdomen–pelvis without contrast (n = 204), abdomen–pelvis with contrast (n = 164), and chest–abdomen–pelvis (n = 61). Only single-phase, standard-range examinations were included. Examinations with major protocol deviations, extended scan ranges, or manual exposure overrides were excluded. CTDIvol and DLP were extracted from DICOM dose reports and reviewed against protocol definitions and scanner dose documentation. Local DRLs were defined as the 75th percentile of the dose distribution for each protocol, and median values were reported as achievable dose indicators. Results: Inter-hospital variability was observed across all protocols, particularly for abdomen–pelvis and chest–abdomen–pelvis examinations. The proposed DLP-based local DRLs (mGy·cm) were: head without contrast, 1179.6; chest without contrast, 425.0; chest with contrast, 1238.0; abdomen–pelvis without contrast, 637.2; abdomen–pelvis with contrast, 1269.9; and chest–abdomen–pelvis, 1411.5. Median values indicated achievable doses below the 75th percentile for all protocols. Compared with selected international studies, abdomen–pelvis doses were broadly comparable, whereas head and chest doses were somewhat higher. Conclusions: This study provides a coordinated multicenter baseline for adult CT local DRLs across EHS hospitals. The findings support protocol harmonization, scan-length optimization, targeted staff training, and integration with dose-monitoring systems to strengthen CT dose optimization and patient safety and to inform future updates of UAE national DRLs.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-04-30
DOI
https://doi.org/10.3390/diagnostics16091353
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishing Local Diagnostic Reference Levels (DRLs) for Adult Computed Tomography in Emirates Health Services Hospitals: A Multicenter Dose Survey

Hatem Ghonim, Mohamed Abuzaid, Amna Alshamsi, Suhaib Alameen et al.
Diagnostics
Radiation Dose and Imaging
article

Establishing Local Diagnostic Reference Levels (DRLs) for Adult Computed Tomography in Emirates Health Services Hospitals: A Multicenter Dose Survey

Hatem Ghonim, Mohamed Abuzaid, Amna Alshamsi, Suhaib Alameen, Sheikha Almsafri, Maryam Alhajri, Amina Aljasmi, Sherif Hani Elkelsh
article en

Abstract

Objectives: This study aimed to establish local Diagnostic Reference Levels (DRLs) for adult computed tomography (CT) across Emirates Health Services (EHS) hospitals in the United Arab Emirates. Methods: A retrospective multicenter survey included 1257 adult patients from seven EHS hospitals who underwent six routine CT protocols: head without contrast (n = 375), chest without contrast (n = 403), chest with contrast (n = 50), abdomen–pelvis without contrast (n = 204), abdomen–pelvis with contrast (n = 164), and chest–abdomen–pelvis (n = 61). Only single-phase, standard-range examinations were included. Examinations with major protocol deviations, extended scan ranges, or manual exposure overrides were excluded. CTDIvol and DLP were extracted from DICOM dose reports and reviewed against protocol definitions and scanner dose documentation. Local DRLs were defined as the 75th percentile of the dose distribution for each protocol, and median values were reported as achievable dose indicators. Results: Inter-hospital variability was observed across all protocols, particularly for abdomen–pelvis and chest–abdomen–pelvis examinations. The proposed DLP-based local DRLs (mGy·cm) were: head without contrast, 1179.6; chest without contrast, 425.0; chest with contrast, 1238.0; abdomen–pelvis without contrast, 637.2; abdomen–pelvis with contrast, 1269.9; and chest–abdomen–pelvis, 1411.5. Median values indicated achievable doses below the 75th percentile for all protocols. Compared with selected international studies, abdomen–pelvis doses were broadly comparable, whereas head and chest doses were somewhat higher. Conclusions: This study provides a coordinated multicenter baseline for adult CT local DRLs across EHS hospitals. The findings support protocol harmonization, scan-length optimization, targeted staff training, and integration with dose-monitoring systems to strengthen CT dose optimization and patient safety and to inform future updates of UAE national DRLs.

DiagnosticsVol. 16(9)
University of Dubai (AE), University of Sharjah (AE), Abu Dhabi Health Services (AE)
Partnerships for the goals
Openalex Percentile: Top 8%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.