Comprehensive Powder Rheological Characterization of Fifteen Lactose-Based Co-Processed and Single-Component Excipients Using FT4 Powder Rheometry and European Pharmacopoeia Methods: A Multi-Parameter Comparative and Correlative Study

Background/Objectives: Co-processed excipients (CPEs) are designed for direct compression through particle engineering, yet comprehensive powder rheological profiles systematically comparing advanced and traditional characterization methods remain limited. This study characterized fifteen lactose-based excipients using European Pharmacopoeia (Ph. Eur.) methods and the complete Freeman FT4 Powder Rheometer measurement suite, establishing a correlation framework linking particle-level attributes to macroscopic flow behavior. Methods: Fifteen excipients were characterized for bulk and tapped density, compressibility index, flow time (Ph. Eur. 2.9.16), and angle of repose (Ph. Eur. 2.9.36). Particle size and shape were measured by dynamic image analysis. FT4 measurements comprised stability and variable flow rate testing, consolidation, aeration, compressibility, permeability, shear cell, and wall friction at three surface roughness. Pearson correlation matrices were computed across all 53 parameters. Results: Classical flow indices classified most CPE as good-to-satisfactory, failing to discriminate materials with fundamentally different dynamic flow profiles. FT4 testing revealed a fourfold range in Basic Flowability Energy (624–2107 mJ), a ninefold range in flow function coefficient (4.3–35.8), and wide aeration sensitivity differences (Aeration Ratio: 1.9–283.7). Strong correlations were identified between Specific Energy and compressibility index (r = 0.85), cohesion and Flow Rate Index (r = 0.79), and Normalized Aeration Sensitivity and pressure drop (r = 0.86). Within-family comparisons (Tablettose 70/80/100, FlowLac 90/100) revealed that particle size distribution breadth is a more critical flow determinant than median size alone. Conclusions: Combining FT4 rheometry with pharmacopoeial testing provides substantially greater discriminating power than either approach alone, enabling rational excipient selection for direct compression formulation.

Authors

Institutions

Publication Details

Journal
Pharmaceutics
Published
2026-04-30
DOI
https://doi.org/10.3390/pharmaceutics18050558
Primary Topic
Drug Solubulity and Delivery Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comprehensive Powder Rheological Characterization of Fifteen Lactose-Based Co-Processed and Single-Component Excipients Using FT4 Powder Rheometry and European Pharmacopoeia Methods: A Multi-Parameter Comparative and Correlative Study

Florian Priese, Jessica Zwanzig, Bertram Wolf, Fabian Herz et al.
Pharmaceutics
Drug Solubulity and Delivery Systems
article

Comprehensive Powder Rheological Characterization of Fifteen Lactose-Based Co-Processed and Single-Component Excipients Using FT4 Powder Rheometry and European Pharmacopoeia Methods: A Multi-Parameter Comparative and Correlative Study

Florian Priese, Jessica Zwanzig, Bertram Wolf, Fabian Herz, Martin Röttig
article en

Abstract

Background/Objectives: Co-processed excipients (CPEs) are designed for direct compression through particle engineering, yet comprehensive powder rheological profiles systematically comparing advanced and traditional characterization methods remain limited. This study characterized fifteen lactose-based excipients using European Pharmacopoeia (Ph. Eur.) methods and the complete Freeman FT4 Powder Rheometer measurement suite, establishing a correlation framework linking particle-level attributes to macroscopic flow behavior. Methods: Fifteen excipients were characterized for bulk and tapped density, compressibility index, flow time (Ph. Eur. 2.9.16), and angle of repose (Ph. Eur. 2.9.36). Particle size and shape were measured by dynamic image analysis. FT4 measurements comprised stability and variable flow rate testing, consolidation, aeration, compressibility, permeability, shear cell, and wall friction at three surface roughness. Pearson correlation matrices were computed across all 53 parameters. Results: Classical flow indices classified most CPE as good-to-satisfactory, failing to discriminate materials with fundamentally different dynamic flow profiles. FT4 testing revealed a fourfold range in Basic Flowability Energy (624–2107 mJ), a ninefold range in flow function coefficient (4.3–35.8), and wide aeration sensitivity differences (Aeration Ratio: 1.9–283.7). Strong correlations were identified between Specific Energy and compressibility index (r = 0.85), cohesion and Flow Rate Index (r = 0.79), and Normalized Aeration Sensitivity and pressure drop (r = 0.86). Within-family comparisons (Tablettose 70/80/100, FlowLac 90/100) revealed that particle size distribution breadth is a more critical flow determinant than median size alone. Conclusions: Combining FT4 rheometry with pharmacopoeial testing provides substantially greater discriminating power than either approach alone, enabling rational excipient selection for direct compression formulation.

PharmaceuticsVol. 18(5)
Anhalt University of Applied Sciences (DE)
Reduced inequalities
Openalex Percentile: Top 10%
Drug Solubulity and Delivery Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.