Transvaginal Shear Wave Elastography for Noninvasive Assessment of Uterine Fibroid and Myometrial Stiffness [ID 1009]

INTRODUCTION: Uterine fibroid (UF) stiffness may contribute to tumor growth, symptom severity, and treatment response. Shear wave elastography (SWE) is a noninvasive, quantitative ultrasound method for measuring tissue stiffness, but it lacks standardization in gynecologic applications. This pilot study aimed to 1) develop a standardized transvaginal SWE protocol to assess myometrial and UF stiffness; 2) evaluate interrater and test–retest reliability; and 3) determine whether stiffness varies by menstrual phase. METHODS: In this prospective pilot study (January to September 2024), 27 women (17 with UFs, 10 without) were enrolled. Each underwent transvaginal SWE imaging during both the follicular and luteal phases of their menstrual cycle. Shear wave elastography values were independently calculated by two raters, with one rater repeating measurements after a 3-month interval to assess reliability. RESULTS: Fifty-one myometrial and 38 UF measurements demonstrated excellent interrater reliability (r=0.97, P <.001). Test–retest reliability was similarly high for 50 myometrial and 42 UF measurements (r=0.95 and r=0.98, respectively; P <.001). Uterine fibroids were significantly stiffer than the surrounding myometrium (median 52.4 versus 32.9 kPa, P <.001). Myometrial stiffness did not differ significantly between women with and without UFs ( P =.6), and menstrual phase had no effect on stiffness values. CONCLUSIONS/IMPLICATIONS: This pilot study establishes a reliable, reproducible protocol for transvaginal SWE in measuring uterine myometrial and UF tissue stiffness. These findings support its feasibility and potential value in personalized assessment and monitoring of UFs in clinical practice.

Authors

Institutions

Publication Details

Journal
Obstetrics and Gynecology
Published
2026-04-30
DOI
https://doi.org/10.1097/aog.0000000000006265.20
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transvaginal Shear Wave Elastography for Noninvasive Assessment of Uterine Fibroid and Myometrial Stiffness [ID 1009]

Ryan E. Longman, Sumeyra Agambayev, Hannah Ryles, Samar Alkhrait et al.
Obstetrics and Gynecology
Ultrasound Imaging and Elastography
article

Transvaginal Shear Wave Elastography for Noninvasive Assessment of Uterine Fibroid and Myometrial Stiffness [ID 1009]

Ryan E. Longman, Sumeyra Agambayev, Hannah Ryles, Samar Alkhrait, Mervat Omran, Ayman Al-Hendy, Obianuju Sandra Madueke-Laveaux
article en

Abstract

INTRODUCTION: Uterine fibroid (UF) stiffness may contribute to tumor growth, symptom severity, and treatment response. Shear wave elastography (SWE) is a noninvasive, quantitative ultrasound method for measuring tissue stiffness, but it lacks standardization in gynecologic applications. This pilot study aimed to 1) develop a standardized transvaginal SWE protocol to assess myometrial and UF stiffness; 2) evaluate interrater and test–retest reliability; and 3) determine whether stiffness varies by menstrual phase. METHODS: In this prospective pilot study (January to September 2024), 27 women (17 with UFs, 10 without) were enrolled. Each underwent transvaginal SWE imaging during both the follicular and luteal phases of their menstrual cycle. Shear wave elastography values were independently calculated by two raters, with one rater repeating measurements after a 3-month interval to assess reliability. RESULTS: Fifty-one myometrial and 38 UF measurements demonstrated excellent interrater reliability (r=0.97, P <.001). Test–retest reliability was similarly high for 50 myometrial and 42 UF measurements (r=0.95 and r=0.98, respectively; P <.001). Uterine fibroids were significantly stiffer than the surrounding myometrium (median 52.4 versus 32.9 kPa, P <.001). Myometrial stiffness did not differ significantly between women with and without UFs ( P =.6), and menstrual phase had no effect on stiffness values. CONCLUSIONS/IMPLICATIONS: This pilot study establishes a reliable, reproducible protocol for transvaginal SWE in measuring uterine myometrial and UF tissue stiffness. These findings support its feasibility and potential value in personalized assessment and monitoring of UFs in clinical practice.

Obstetrics and GynecologyVol. 147(5S)
University of Chicago (US)
Good health and well-being
Openalex Percentile: Top 8%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Transvaginal Shear Wave Elastography for Noninvasive Assessment of Uterine Fibroid and Myometrial Stiffness [ID 1009] — Ryan E. Longman, Sumeyra Agambayev, et al. · Obstetrics and Gynecology (2026) | TGRS Research Map | TGRS