Bleb Compressive Sutures in Descemet Stripping Automated Endothelial Keratoplasty for Eyes with Filtering Blebs Following Trabeculectomy

Background/Objectives: A disadvantage of Descemet stripping automated endothelial keratoplasty (DSAEK) in eyes with prior glaucoma filtration surgery is the difficulty in maintaining air tamponade during the procedure. Herein, we report the use of bleb compressive sutures in managing air tamponade in the anterior chamber during DSAEK in eyes with blebs following trabeculectomy. Methods: This retrospective case series included 34 eyes of 33 patients that developed bullous keratopathy following trabeculectomy. Bleb compression suturing was performed using a 10-0 nylon suture in eyes with an intraocular pressure (IOP) < 10 mmHg or a fragile ischemic bleb. Postoperative IOP, air ingress into the bleb, rebubbling, bleb leakage, and bleb damage were evaluated. Results: Of the 34 eyes, 13 underwent bleb compression suturing before DSAEK (suture group), whereas 21 eyes did not (non-suture group). The mean preoperative IOP was 7.5 ± 2.5 mmHg and 11.2 ± 4.2 mmHg in the suture and the non-suture groups, respectively. The IOP was measured 2 h postoperatively in 14 eyes, increasing by 18 ± 9.3 and 11.7 ± 3.1 mmHg in the suture and non-suture groups, respectively, compared to the preoperative IOP, with no significant differences. At 2 h postoperatively, two eyes in the suture group and one eye in the non-suture group exhibited an IOP spike (≥30 mmHg). One eye in the non-suture group required rebubbling owing to air ingress into the bleb. The mean IOP was 7.1 ± 3.2 and 9.4 ± 4.6 mmHg in the suture and non-suture groups, respectively, 1–2 weeks postoperatively. Preoperative and postoperative IOPs did not significantly differ in either group, and no suture-related complications were observed. Conclusions: For eyes with blebs, bleb compression suturing in DSAEK provides effective air tamponade during graft adhesion.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-04-30
DOI
https://doi.org/10.3390/jcm15093439
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bleb Compressive Sutures in Descemet Stripping Automated Endothelial Keratoplasty for Eyes with Filtering Blebs Following Trabeculectomy

Kaoru Araki‐Sasaki, Noriko Toyokawa, Hideya Kimura, Shinichiro Kuroda
Journal of Clinical Medicine
Glaucoma and retinal disorders
article

Bleb Compressive Sutures in Descemet Stripping Automated Endothelial Keratoplasty for Eyes with Filtering Blebs Following Trabeculectomy

Kaoru Araki‐Sasaki, Noriko Toyokawa, Hideya Kimura, Shinichiro Kuroda
article en

Abstract

Background/Objectives: A disadvantage of Descemet stripping automated endothelial keratoplasty (DSAEK) in eyes with prior glaucoma filtration surgery is the difficulty in maintaining air tamponade during the procedure. Herein, we report the use of bleb compressive sutures in managing air tamponade in the anterior chamber during DSAEK in eyes with blebs following trabeculectomy. Methods: This retrospective case series included 34 eyes of 33 patients that developed bullous keratopathy following trabeculectomy. Bleb compression suturing was performed using a 10-0 nylon suture in eyes with an intraocular pressure (IOP) < 10 mmHg or a fragile ischemic bleb. Postoperative IOP, air ingress into the bleb, rebubbling, bleb leakage, and bleb damage were evaluated. Results: Of the 34 eyes, 13 underwent bleb compression suturing before DSAEK (suture group), whereas 21 eyes did not (non-suture group). The mean preoperative IOP was 7.5 ± 2.5 mmHg and 11.2 ± 4.2 mmHg in the suture and the non-suture groups, respectively. The IOP was measured 2 h postoperatively in 14 eyes, increasing by 18 ± 9.3 and 11.7 ± 3.1 mmHg in the suture and non-suture groups, respectively, compared to the preoperative IOP, with no significant differences. At 2 h postoperatively, two eyes in the suture group and one eye in the non-suture group exhibited an IOP spike (≥30 mmHg). One eye in the non-suture group required rebubbling owing to air ingress into the bleb. The mean IOP was 7.1 ± 3.2 and 9.4 ± 4.6 mmHg in the suture and non-suture groups, respectively, 1–2 weeks postoperatively. Preoperative and postoperative IOPs did not significantly differ in either group, and no suture-related complications were observed. Conclusions: For eyes with blebs, bleb compression suturing in DSAEK provides effective air tamponade during graft adhesion.

Journal of Clinical MedicineVol. 15(9)
Kansai Medical University (JP)
Openalex Percentile: Top 7%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.