Ultrasonic feature-based regression of DP, breakdown voltage, and dielectric loss in transformer oil–paper insulation

Oil–paper insulation aging is a major cause of power transformer deterioration, yet key indices, such as paper degree of polymerization (DP), oil breakdown voltage (Ubd), and dielectric loss factor (tanδ), are still mainly obtained through laboratory tests. These indices require individual measurement with distinct equipment, making the whole process tedious and time-consuming. This work investigates whether single-channel ultrasonic measurements of transformer oil can be used to estimate these three indices within a unified regression framework. A controlled thermal-aging experiment was carried out on an oil–paper insulation system at seven aging stages (0–32 days). At each stage, 20 samples were tested, and each sample was paired with its own measured DP, Ubd, and tanδ values. From each waveform, 20 physically interpretable time-, frequency-, and envelope-domain features were extracted. A regularized feature-based regression model was then developed and evaluated primarily by sample-wise stratified fivefold cross-validation, while leave-one-stage-out (LOSO) validation was additionally used as a stricter test of cross-stage generalization. Under the main sample-wise cross-validation protocol, the pooled predictions achieved R2 values of 0.988, 0.827, and 0.991 and NRMSE values of 3.5%, 10.5%, and 3.1% for DP, Ubd, and tanδ, respectively. In the supplementary LOSO evaluation, predictive performance decreased. Overall, these results demonstrate that ultrasonic features enable reliable estimation of multiple insulation indices under controlled laboratory thermal-aging conditions.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2026-05-01
DOI
https://doi.org/10.1063/5.0321700
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasonic feature-based regression of DP, breakdown voltage, and dielectric loss in transformer oil–paper insulation

Zikai Jiang, Shiyezi Xiang, Zhou Fan, Weizhe Guo et al.
AIP Advances
Power Transformer Diagnostics and Insulation
article

Ultrasonic feature-based regression of DP, breakdown voltage, and dielectric loss in transformer oil–paper insulation

Zikai Jiang, Shiyezi Xiang, Zhou Fan, Weizhe Guo, Jingxin Zou, Dingkun Yang
article en

Abstract

Oil–paper insulation aging is a major cause of power transformer deterioration, yet key indices, such as paper degree of polymerization (DP), oil breakdown voltage (Ubd), and dielectric loss factor (tanδ), are still mainly obtained through laboratory tests. These indices require individual measurement with distinct equipment, making the whole process tedious and time-consuming. This work investigates whether single-channel ultrasonic measurements of transformer oil can be used to estimate these three indices within a unified regression framework. A controlled thermal-aging experiment was carried out on an oil–paper insulation system at seven aging stages (0–32 days). At each stage, 20 samples were tested, and each sample was paired with its own measured DP, Ubd, and tanδ values. From each waveform, 20 physically interpretable time-, frequency-, and envelope-domain features were extracted. A regularized feature-based regression model was then developed and evaluated primarily by sample-wise stratified fivefold cross-validation, while leave-one-stage-out (LOSO) validation was additionally used as a stricter test of cross-stage generalization. Under the main sample-wise cross-validation protocol, the pooled predictions achieved R2 values of 0.988, 0.827, and 0.991 and NRMSE values of 3.5%, 10.5%, and 3.1% for DP, Ubd, and tanδ, respectively. In the supplementary LOSO evaluation, predictive performance decreased. Overall, these results demonstrate that ultrasonic features enable reliable estimation of multiple insulation indices under controlled laboratory thermal-aging conditions.

AIP AdvancesVol. 16(5)
Chongqing University of Posts and Telecommunications (CN), Electric Power Research Institute (US), State Grid Corporation of China (China) (CN), University of Toronto (CA), Shanghai Electric (China) (CN)
Natural Science Foundation of Chongqing
Openalex Percentile: Top 13%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.