Determination of Ground Clearance for EHV 400 kV Overhead Power Lines Based on Electromagnetic Field Limits

The planning and design of Extra-High Voltage (EHV) overhead power lines require strict adherence to electromagnetic field exposure limits to ensure public safety. This paper presents a comprehensive analysis of the minimum ground clearance required for standard 400 kV transmission towers to comply with international safety guidelines. A review of legislative frameworks across 37 countries indicates a widespread consensus on limiting values of 5 kV/m for the electric field and 100 μT for magnetic flux density. Using analytical methods, the electric and magnetic fields were calculated for four common tower geometries (Cat, Portal, Danube, and Barrel) under varying ground clearances and phase configurations. The results demonstrate that the magnetic flux density is not a limiting factor, as it remains well below safety thresholds even at standard technical clearances. Conversely, the electric field intensity proves to be the critical design constraint, often requiring clearances significantly higher than those dictated by insulation coordination. The study identifies that optimizing the phase sequence in double-circuit towers can reduce the required ground clearance by up to 28%, offering a cost-effective mitigation strategy. These findings provide power line designers with essential decision-making data for the preliminary design phase, enabling the optimization of tower geometry and phase arrangement without the need for computationally intensive simulations.

Authors

Institutions

Publication Details

Journal
Electricity
Published
2026-05-01
DOI
https://doi.org/10.3390/electricity7020039
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Ground Clearance for EHV 400 kV Overhead Power Lines Based on Electromagnetic Field Limits

Matej Cenký, Žaneta Eleschová, Jozef Bendík
Electricity
Lightning and Electromagnetic Phenomena
article

Determination of Ground Clearance for EHV 400 kV Overhead Power Lines Based on Electromagnetic Field Limits

Matej Cenký, Žaneta Eleschová, Jozef Bendík
article en

Abstract

The planning and design of Extra-High Voltage (EHV) overhead power lines require strict adherence to electromagnetic field exposure limits to ensure public safety. This paper presents a comprehensive analysis of the minimum ground clearance required for standard 400 kV transmission towers to comply with international safety guidelines. A review of legislative frameworks across 37 countries indicates a widespread consensus on limiting values of 5 kV/m for the electric field and 100 μT for magnetic flux density. Using analytical methods, the electric and magnetic fields were calculated for four common tower geometries (Cat, Portal, Danube, and Barrel) under varying ground clearances and phase configurations. The results demonstrate that the magnetic flux density is not a limiting factor, as it remains well below safety thresholds even at standard technical clearances. Conversely, the electric field intensity proves to be the critical design constraint, often requiring clearances significantly higher than those dictated by insulation coordination. The study identifies that optimizing the phase sequence in double-circuit towers can reduce the required ground clearance by up to 28%, offering a cost-effective mitigation strategy. These findings provide power line designers with essential decision-making data for the preliminary design phase, enabling the optimization of tower geometry and phase arrangement without the need for computationally intensive simulations.

ElectricityVol. 7(2)
Slovak University of Technology in Bratislava (SK)
Agentúra na Podporu Výskumu a Vývoja
Openalex Percentile: Top 7%
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determination of Ground Clearance for EHV 400 kV Overhead Power Lines Based on Electromagnetic Field Limits — Matej Cenký, Žaneta Eleschová, et al. · Electricity (2026) | TGRS Research Map | TGRS