Wirelessly Interrogated, Implantable Capacitive MEMS Sensors for Continuous Intraocular Pressure Monitoring

This work presents wirelessly interrogated microelectromechanical system (MEMS) capacitive sensors for continuous intraocular pressure (IOP) monitoring. The sensor uses a passive inductor–capacitor (LC) tank circuit comprising a fixed, on-chip spiral inductor and a pressure-sensitive, variable-gap capacitor with parallel-plate membrane electrodes and side anchors. The membrane is designed with dimensions of 500 µm × 500 µm × 2 µm and a capacitive transducer gap of 2.5 µm. Applied pressure deflects the top membrane, producing a corresponding capacitance variation that changes the frequency and phase response of the LC tank circuit, enabling real-time and continuous IOP monitoring over a target detection range of 0–50 mmHg and beyond. Mutual inductive coupling between the sensor and the external readout coil is investigated as a reliable readout mechanism.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-04-30
DOI
https://doi.org/10.3390/s26092806
Primary Topic
Wireless Power Transfer Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wirelessly Interrogated, Implantable Capacitive MEMS Sensors for Continuous Intraocular Pressure Monitoring

Adnan Zaman, Liguan Li, Ramesh Ayyala, Jing Wang
Sensors
Wireless Power Transfer Systems
article

Wirelessly Interrogated, Implantable Capacitive MEMS Sensors for Continuous Intraocular Pressure Monitoring

Adnan Zaman, Liguan Li, Ramesh Ayyala, Jing Wang
article en

Abstract

This work presents wirelessly interrogated microelectromechanical system (MEMS) capacitive sensors for continuous intraocular pressure (IOP) monitoring. The sensor uses a passive inductor–capacitor (LC) tank circuit comprising a fixed, on-chip spiral inductor and a pressure-sensitive, variable-gap capacitor with parallel-plate membrane electrodes and side anchors. The membrane is designed with dimensions of 500 µm × 500 µm × 2 µm and a capacitive transducer gap of 2.5 µm. Applied pressure deflects the top membrane, producing a corresponding capacitance variation that changes the frequency and phase response of the LC tank circuit, enabling real-time and continuous IOP monitoring over a target detection range of 0–50 mmHg and beyond. Mutual inductive coupling between the sensor and the external readout coil is investigated as a reliable readout mechanism.

SensorsVol. 26(9)
King Abdulaziz City for Science and Technology (SA), University of South Florida (US)
U.S. Army Medical Research and Development Command
Affordable and clean energy
Openalex Percentile: Top 11%
Wireless Power Transfer Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.