Hardware-Agnostic Imitation Learning Method for Autonomous Ultrasound Scanning Addressing Physical Deployment Discrepancies

To achieve autonomous ultrasound scanning skill transfer across different physical equipment instances and address the limitations of traditional imitation learning methods—which struggle with cross-instance generalization due to their reliance on specific manipulator parameters—this study proposes a physical-parameter-decoupled imitation learning method based on waypoint representation. This approach utilizes a greedy algorithm to automatically extract key nodes within the task space from expert demonstration trajectories, constructing a trajectory representation decoupled from low-level kinematic parameters and base calibration errors. Simultaneously, a velocity-aware adaptive error precision adjustment mechanism is introduced to dynamically modulate waypoint extraction thresholds, simulating the speed-accuracy strategies employed by sonographers across different scanning phases. Cross-validation across two mainstream generative architectures—Action Chunking Transformer (ACT) and Diffusion Policy—on an offline dataset confirms the plug-and-play capability of waypoint representation in suppressing long-horizon error accumulation, with both architectures achieving significant reductions in prediction errors. For physical deployment, a complete ACT-waypoint system featuring low-level triple safety redundancy was validated. In kidney long-axis standard plane scanning tasks, the system achieved a 92% success rate on the source domain manipulator and maintained an 84% success rate on the target deployment manipulator, despite incompatible low-level kinematic parameters and base coordinates. Force control accuracy remained stable around the target value of 12 N. The results demonstrate that the proposed method effectively overcomes base coordinate and D-H parameter discrepancies to achieve cross-instance zero-shot skill transfer, significantly enhancing the adaptability across physical instances and the scanning success rate of imitation learning models.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-04-30
DOI
https://doi.org/10.3390/s26092804
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hardware-Agnostic Imitation Learning Method for Autonomous Ultrasound Scanning Addressing Physical Deployment Discrepancies

Yongkang Tang, Zhuoyang Ma, Jing Xia, Hongbo Zhu et al.
Sensors
Soft Robotics and Applications
article

Hardware-Agnostic Imitation Learning Method for Autonomous Ultrasound Scanning Addressing Physical Deployment Discrepancies

Yongkang Tang, Zhuoyang Ma, Jing Xia, Hongbo Zhu, Hong Gao
article en

Abstract

To achieve autonomous ultrasound scanning skill transfer across different physical equipment instances and address the limitations of traditional imitation learning methods—which struggle with cross-instance generalization due to their reliance on specific manipulator parameters—this study proposes a physical-parameter-decoupled imitation learning method based on waypoint representation. This approach utilizes a greedy algorithm to automatically extract key nodes within the task space from expert demonstration trajectories, constructing a trajectory representation decoupled from low-level kinematic parameters and base calibration errors. Simultaneously, a velocity-aware adaptive error precision adjustment mechanism is introduced to dynamically modulate waypoint extraction thresholds, simulating the speed-accuracy strategies employed by sonographers across different scanning phases. Cross-validation across two mainstream generative architectures—Action Chunking Transformer (ACT) and Diffusion Policy—on an offline dataset confirms the plug-and-play capability of waypoint representation in suppressing long-horizon error accumulation, with both architectures achieving significant reductions in prediction errors. For physical deployment, a complete ACT-waypoint system featuring low-level triple safety redundancy was validated. In kidney long-axis standard plane scanning tasks, the system achieved a 92% success rate on the source domain manipulator and maintained an 84% success rate on the target deployment manipulator, despite incompatible low-level kinematic parameters and base coordinates. Force control accuracy remained stable around the target value of 12 N. The results demonstrate that the proposed method effectively overcomes base coordinate and D-H parameter discrepancies to achieve cross-instance zero-shot skill transfer, significantly enhancing the adaptability across physical instances and the scanning success rate of imitation learning models.

SensorsVol. 26(9)
Xi'an University of Science and Technology (CN)
Openalex Percentile: Top 12%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.