Maternal Salivary Glutamate Concentrations in Cesarean Delivery: A Prospective Comparison Between Spinal and General Anesthesia

Background: Cesarean delivery is commonly performed under either spinal or general anesthesia. While both techniques are widely used, their differential effects on maternal neurochemical profiles, particularly excitatory neurotransmitters such as glutamate, remain incompletely understood. Glutamate plays a central role in stress response, nociception, and neuroendocrine regulation. This study aimed to compare maternal salivary glutamate concentrations between spinal and general anesthesia during cesarean delivery. Method: In this prospective study, 66 women undergoing cesarean delivery were included: 32 received spinal anesthesia and 34 received general anesthesia. Unstimulated saliva samples were collected perioperatively and analyzed using a colorimetric enzymatic assay. Clinical and demographic variables were extracted from electronic medical records. Results: Baseline maternal and neonatal characteristics were comparable between groups (all p > 0.05). Glutamate concentrations were not normally distributed. Median salivary glutamate levels were significantly higher in the general anesthesia group compared with the spinal anesthesia group (8.05 nmol/µL [IQR 4.81–11.69] vs. 5.19 nmol/µL [IQR 3.05–8.39]; p = 0.041) After adjustment for maternal and perinatal covariates, anesthesia type was not independently associated with glutamate levels (p = 0.21). Conclusion: General anesthesia was associated with higher unadjusted maternal salivary glutamate levels compared with spinal anesthesia during cesarean delivery; however, this association did not persist after multivariable adjustment. These findings suggest that anesthesia technique alone may not independently influence perioperative glutamatergic responses. Further research is warranted to clarify the clinical significance of these neurochemical changes for maternal and neonatal outcomes.

Authors

Institutions

Publication Details

Journal
Life
Published
2026-05-01
DOI
https://doi.org/10.3390/life16050748
Primary Topic
Anesthesia and Neurotoxicity Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Maternal Salivary Glutamate Concentrations in Cesarean Delivery: A Prospective Comparison Between Spinal and General Anesthesia

Omar F. Altal, Anas Alrusan, Diab Bani Hani, Atef F. Hulliel et al.
Life
Anesthesia and Neurotoxicity Research
article

Maternal Salivary Glutamate Concentrations in Cesarean Delivery: A Prospective Comparison Between Spinal and General Anesthesia

Omar F. Altal, Anas Alrusan, Diab Bani Hani, Atef F. Hulliel, Mohammad Al Hazaymeh, Ala”a Alhowary, Fatima Albusta, Taqwa Haweeleh, Tala Ahmed
article en

Abstract

Background: Cesarean delivery is commonly performed under either spinal or general anesthesia. While both techniques are widely used, their differential effects on maternal neurochemical profiles, particularly excitatory neurotransmitters such as glutamate, remain incompletely understood. Glutamate plays a central role in stress response, nociception, and neuroendocrine regulation. This study aimed to compare maternal salivary glutamate concentrations between spinal and general anesthesia during cesarean delivery. Method: In this prospective study, 66 women undergoing cesarean delivery were included: 32 received spinal anesthesia and 34 received general anesthesia. Unstimulated saliva samples were collected perioperatively and analyzed using a colorimetric enzymatic assay. Clinical and demographic variables were extracted from electronic medical records. Results: Baseline maternal and neonatal characteristics were comparable between groups (all p > 0.05). Glutamate concentrations were not normally distributed. Median salivary glutamate levels were significantly higher in the general anesthesia group compared with the spinal anesthesia group (8.05 nmol/µL [IQR 4.81–11.69] vs. 5.19 nmol/µL [IQR 3.05–8.39]; p = 0.041) After adjustment for maternal and perinatal covariates, anesthesia type was not independently associated with glutamate levels (p = 0.21). Conclusion: General anesthesia was associated with higher unadjusted maternal salivary glutamate levels compared with spinal anesthesia during cesarean delivery; however, this association did not persist after multivariable adjustment. These findings suggest that anesthesia technique alone may not independently influence perioperative glutamatergic responses. Further research is warranted to clarify the clinical significance of these neurochemical changes for maternal and neonatal outcomes.

LifeVol. 16(5)
Jordan University of Science and Technology (JO)
Jordan University of Science and Technology
Good health and well-being
Openalex Percentile: Top 10%
Anesthesia and Neurotoxicity Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.