Optimizing EMG-Based Transtibial Movement Classification for Real-Time Prosthetic Control: A Feature Engineering and Multi-Window Voting Study

Objective: This study investigates the optimization of surface EMG (sEMG) classification for seven transtibial movements using short analysis windows (64 ms) suitable for real-time control of below-knee prostheses. Methods: We systematically evaluated feature engineering strategies, dimensionality reduction techniques, and classification approaches using linear Support Vector Machines on four-channel sEMG data from the transtibial region. We compared amplitude-based versus derivative-based time-domain features, integrated frequency-domain features, and implemented multi-window majority voting with 50% overlap. Results: Evaluated across nine subjects (four male, five female), the optimized system achieves a population-level accuracy of 70.16%±7.09% with multi-window majority voting (per-subject range: 60.71–78.57%), with voting consistently improving accuracy over single-window classification by +7.06% on average. We demonstrate that PCA provides zero benefit for linear classifiers when all features are retained. Documented failed approaches include adaptive windowing and spectral entropy features. Conclusion: Careful feature engineering combining time-domain (MAV2, RMS, VAR, MAX, LOG, IEMG) and frequency-domain features (MPF, MF, band powers) with multi-window voting substantially recovers accuracy losses from aggressive window reduction while maintaining sub-100 ms latency suitable for prosthetic control. This work provides a validated methodology across multiple subjects for optimizing EMG classification latency–accuracy trade-offs, demonstrates that PCA is unnecessary for linear classifiers with well-engineered features, and documents negative results to guide future prosthetic control research.

Authors

Institutions

Publication Details

Journal
Algorithms
Published
2026-05-01
DOI
https://doi.org/10.3390/a19050351
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing EMG-Based Transtibial Movement Classification for Real-Time Prosthetic Control: A Feature Engineering and Multi-Window Voting Study

Diana C. Toledo-Pérez, Marcos Avilés, Roberto A. Gómez‐Loenzo, Carlos Gabriel Mireles-Preciado et al.
Algorithms
Muscle activation and electromyography studies
article

Optimizing EMG-Based Transtibial Movement Classification for Real-Time Prosthetic Control: A Feature Engineering and Multi-Window Voting Study

Diana C. Toledo-Pérez, Marcos Avilés, Roberto A. Gómez‐Loenzo, Carlos Gabriel Mireles-Preciado, Juvenal Rodríguez-Resendiz
article en

Abstract

Objective: This study investigates the optimization of surface EMG (sEMG) classification for seven transtibial movements using short analysis windows (64 ms) suitable for real-time control of below-knee prostheses. Methods: We systematically evaluated feature engineering strategies, dimensionality reduction techniques, and classification approaches using linear Support Vector Machines on four-channel sEMG data from the transtibial region. We compared amplitude-based versus derivative-based time-domain features, integrated frequency-domain features, and implemented multi-window majority voting with 50% overlap. Results: Evaluated across nine subjects (four male, five female), the optimized system achieves a population-level accuracy of 70.16%±7.09% with multi-window majority voting (per-subject range: 60.71–78.57%), with voting consistently improving accuracy over single-window classification by +7.06% on average. We demonstrate that PCA provides zero benefit for linear classifiers when all features are retained. Documented failed approaches include adaptive windowing and spectral entropy features. Conclusion: Careful feature engineering combining time-domain (MAV2, RMS, VAR, MAX, LOG, IEMG) and frequency-domain features (MPF, MF, band powers) with multi-window voting substantially recovers accuracy losses from aggressive window reduction while maintaining sub-100 ms latency suitable for prosthetic control. This work provides a validated methodology across multiple subjects for optimizing EMG classification latency–accuracy trade-offs, demonstrates that PCA is unnecessary for linear classifiers with well-engineered features, and documents negative results to guide future prosthetic control research.

AlgorithmsVol. 19(5)
Autonomous University of Queretaro (MX)
Gender equality
Openalex Percentile: Top 12%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.