Sustainability of selected ion flow tube mass spectrometry (SIFT-MS): the case of breath analysis

BACKGROUND: The growing focus on sustainability in analytical chemistry calls for systematic evaluation of environmental, practical and economic aspects of all workflows. Selected ion flow tube mass spectrometry (SIFT-MS) is a real-time technique for volatile organic compound (VOC) detection, widely applied in breath analysis. SIFT-MS is a highly versatile instrument that supports three different sampling modes: direct, bags and thermal desorption, which can be selected according to the specific application and clinical study design. RESULTS: In this work, we applied established evaluation frameworks to assess the three SIFT-MS breath sampling modes, considering different dimensions of sustainability: green, as method environmental impact, blue, as practical applicability of the method, red, as method performance, and white as overall method evaluation. Each of the three modes achieved high sustainability scores (e.g. >80/100 green assessment) across the different evaluation tools, confirming the intrinsically sustainable nature of both the SIFT-MS and breath as biological matrix. Minor differences among the sampling techniques were observed, mainly related to sample collection and automation. SIGNIFICANCE: Our aim is to provide a comprehensive assessment that enables users to make informed decisions when selecting the most appropriate technique for their specific needs in breath analysis. The study highlighted the need to adapt sustainability evaluation tools to emerging non-invasive matrices, such as breath, and reagent-free new generation instruments, like SIFT-MS. Overall, breath analysis by SIFT-MS represents a promising example of low-impact analytical techniques despite minor consumable waste (e.g. sample collection materials), that could lead in the future toward a zero-waste workflow.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2026-04-30
DOI
https://doi.org/10.1016/j.talanta.2026.129924
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sustainability of selected ion flow tube mass spectrometry (SIFT-MS): the case of breath analysis

Ilaria Belluomo, Patrik Spanel, Vaughan S. Langford, George B. Hanna et al.
Talanta
Advanced Chemical Sensor Technologies
article

Sustainability of selected ion flow tube mass spectrometry (SIFT-MS): the case of breath analysis

Ilaria Belluomo, Patrik Spanel, Vaughan S. Langford, George B. Hanna, Mark J. Perkins
article en

Abstract

BACKGROUND: The growing focus on sustainability in analytical chemistry calls for systematic evaluation of environmental, practical and economic aspects of all workflows. Selected ion flow tube mass spectrometry (SIFT-MS) is a real-time technique for volatile organic compound (VOC) detection, widely applied in breath analysis. SIFT-MS is a highly versatile instrument that supports three different sampling modes: direct, bags and thermal desorption, which can be selected according to the specific application and clinical study design. RESULTS: In this work, we applied established evaluation frameworks to assess the three SIFT-MS breath sampling modes, considering different dimensions of sustainability: green, as method environmental impact, blue, as practical applicability of the method, red, as method performance, and white as overall method evaluation. Each of the three modes achieved high sustainability scores (e.g. >80/100 green assessment) across the different evaluation tools, confirming the intrinsically sustainable nature of both the SIFT-MS and breath as biological matrix. Minor differences among the sampling techniques were observed, mainly related to sample collection and automation. SIGNIFICANCE: Our aim is to provide a comprehensive assessment that enables users to make informed decisions when selecting the most appropriate technique for their specific needs in breath analysis. The study highlighted the need to adapt sustainability evaluation tools to emerging non-invasive matrices, such as breath, and reagent-free new generation instruments, like SIFT-MS. Overall, breath analysis by SIFT-MS represents a promising example of low-impact analytical techniques despite minor consumable waste (e.g. sample collection materials), that could lead in the future toward a zero-waste workflow.

TalantaVol. 308
Vinci (United Kingdom) (GB), Christchurch Clinical Studies Trust (NZ), Czech Academy of Sciences, J. Heyrovský Institute of Physical Chemistry (CZ), Imperial College London (GB)
Responsible consumption and production
Openalex Percentile: Top 16%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.