Analysis of the external network parameters influence on the operating characteristics of self-excited induction generators

Introduction. Self-excited induction generators (SEIGs) play a vital role in renewable energy systems, particularly in remote regions. However, their performance is highly sensitive to excitation capacitance, rotor speed and load variations, making stability and reliability key challenges. Problem. Simplified analytical models fail to capture the complex internal interactions within SEIGs, limiting the analysis of how external network variations influence their dynamics. Moreover, the gradual degradation of excitation capacitors, a common fault in practice, significantly reduces generator efficiency. The goal of this work is to analyze the influence of excitation capacitance, rotor speed and load variations on SEIG performance, focusing on gradual capacitor degradation and open-phase faults to provide guidelines for reliable and efficient design. Methodology. Finite element modeling (FEM) with ANSYS Maxwell is used to accurately simulate electromagnetic and mechanical dynamics under realistic operating conditions. Results. Simulations show how changes in capacitance, rotor speed and load greatly affect voltage and current stability. Capacitor faults and open-phase conditions cause current distortion, voltage unbalance and reduced efficiency. Scientific novelty of this work lies in the FEM-based analysis of gradual excitation capacitor degradation in SEIGs. It was determined that this degradation directly impacts voltage balance, current waveform distortion and overall efficiency. Practical value. The findings provide clear guidelines for selecting optimal excitation capacitance and load ranges, reducing costs while enhancing the reliability and efficiency of SEIGs, particularly in isolated regions. Also this study offers new physical insight and a reliable framework for generator condition monitoring and design optimization. References 24, tables 1, figures 12.

Authors

Institutions

Publication Details

Journal
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Published
2026-05-02
Primary Topic
Wind Turbine Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the external network parameters influence on the operating characteristics of self-excited induction generators

N. Yassa, A. Dilmi, B. Fares, A. Bouzida
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Wind Turbine Control Systems
article

Analysis of the external network parameters influence on the operating characteristics of self-excited induction generators

N. Yassa, A. Dilmi, B. Fares, A. Bouzida
article en

Abstract

Introduction. Self-excited induction generators (SEIGs) play a vital role in renewable energy systems, particularly in remote regions. However, their performance is highly sensitive to excitation capacitance, rotor speed and load variations, making stability and reliability key challenges. Problem. Simplified analytical models fail to capture the complex internal interactions within SEIGs, limiting the analysis of how external network variations influence their dynamics. Moreover, the gradual degradation of excitation capacitors, a common fault in practice, significantly reduces generator efficiency. The goal of this work is to analyze the influence of excitation capacitance, rotor speed and load variations on SEIG performance, focusing on gradual capacitor degradation and open-phase faults to provide guidelines for reliable and efficient design. Methodology. Finite element modeling (FEM) with ANSYS Maxwell is used to accurately simulate electromagnetic and mechanical dynamics under realistic operating conditions. Results. Simulations show how changes in capacitance, rotor speed and load greatly affect voltage and current stability. Capacitor faults and open-phase conditions cause current distortion, voltage unbalance and reduced efficiency. Scientific novelty of this work lies in the FEM-based analysis of gradual excitation capacitor degradation in SEIGs. It was determined that this degradation directly impacts voltage balance, current waveform distortion and overall efficiency. Practical value. The findings provide clear guidelines for selecting optimal excitation capacitance and load ranges, reducing costs while enhancing the reliability and efficiency of SEIGs, particularly in isolated regions. Also this study offers new physical insight and a reliable framework for generator condition monitoring and design optimization. References 24, tables 1, figures 12.

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
University of Béjaïa (DZ), University of Bouira (DZ)
Affordable and clean energy
Openalex Percentile: Top 12%
Wind Turbine Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.