Performance improvement of sensorless scalar and vector control for induction motor drives via an enhanced voltage model

Introduction. Scalar control (SC) and field-oriented control (FOC) are widely used in sensorless induction motor (IM) drives for their balance of performance and cost. Among estimation techniques, the voltage-model (VM) based model reference adaptive system (MRAS) is preferred in industry due to its simple structure and low computational load. Problem. Traditional VM-based MRAS schemes are highly sensitive to parameter uncertainties, especially to variations in stator resistance Rs caused by temperature changes. These variations degrade flux estimation accuracy, leading to significant speed-tracking errors, increased transients, and reduced stability in both SC and FOC. Goal. This study quantitatively evaluates how the estimation of stator resistance Rs and the dependent rotor resistance Rr affects the speed-control performance of sensorless SC and FOC under parameter mismatch. Methodology. An improved VM-based MRAS is proposed with parallel Rs estimation and Rr updated via a linear relation to Rs. Estimator stability and convergence are proven using Lyapunov theory. The estimator is integrated into SC and FOC and tested in MATLAB/Simulink under identical conditions, including a sudden 30 % increase in resistance. Speed tracking is quantified using the integral of time-weighted absolute error (ITAE). Results. Parameter estimation markedly enhances the robustness of both strategies. In sensorless SC, ITAE drops by about 66.2 % (5.512 to 1.863), indicating much lower transient oscillations. In sensorless FOC, ITAE falls by about 54 % (0.7075 to 0.323), with speed overshoot nearly eliminated (0.031). Scientific novelty. The study provides a unified quantitative comparison of sensorless SC and FOC using ITAE under identical operating and estimation conditions, revealing different levels of performance recovery with the proposed dual-resistance adaptation. Practical value. The findings guide the design of more reliable industrial IM drives, showing that while FOC retains superior dynamics, SC with estimation becomes a robust, cost-effective option for applications with significant parameter uncertainty. References 31, table 1, figures 13.

Authors

Institutions

Publication Details

Journal
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Published
2026-05-02
Primary Topic
Sensorless Control of Electric Motors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance improvement of sensorless scalar and vector control for induction motor drives via an enhanced voltage model

M. Kuchar, P. D. Nguyen
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Sensorless Control of Electric Motors
article

Performance improvement of sensorless scalar and vector control for induction motor drives via an enhanced voltage model

M. Kuchar, P. D. Nguyen
article en

Abstract

Introduction. Scalar control (SC) and field-oriented control (FOC) are widely used in sensorless induction motor (IM) drives for their balance of performance and cost. Among estimation techniques, the voltage-model (VM) based model reference adaptive system (MRAS) is preferred in industry due to its simple structure and low computational load. Problem. Traditional VM-based MRAS schemes are highly sensitive to parameter uncertainties, especially to variations in stator resistance Rs caused by temperature changes. These variations degrade flux estimation accuracy, leading to significant speed-tracking errors, increased transients, and reduced stability in both SC and FOC. Goal. This study quantitatively evaluates how the estimation of stator resistance Rs and the dependent rotor resistance Rr affects the speed-control performance of sensorless SC and FOC under parameter mismatch. Methodology. An improved VM-based MRAS is proposed with parallel Rs estimation and Rr updated via a linear relation to Rs. Estimator stability and convergence are proven using Lyapunov theory. The estimator is integrated into SC and FOC and tested in MATLAB/Simulink under identical conditions, including a sudden 30 % increase in resistance. Speed tracking is quantified using the integral of time-weighted absolute error (ITAE). Results. Parameter estimation markedly enhances the robustness of both strategies. In sensorless SC, ITAE drops by about 66.2 % (5.512 to 1.863), indicating much lower transient oscillations. In sensorless FOC, ITAE falls by about 54 % (0.7075 to 0.323), with speed overshoot nearly eliminated (0.031). Scientific novelty. The study provides a unified quantitative comparison of sensorless SC and FOC using ITAE under identical operating and estimation conditions, revealing different levels of performance recovery with the proposed dual-resistance adaptation. Practical value. The findings guide the design of more reliable industrial IM drives, showing that while FOC retains superior dynamics, SC with estimation becomes a robust, cost-effective option for applications with significant parameter uncertainty. References 31, table 1, figures 13.

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
VSB - Technical University of Ostrava (CZ), Saigon University (VN)
Industry, innovation and infrastructure
Openalex Percentile: Top 10%
Sensorless Control of Electric Motors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.