Comprehensive Quantitative Urinary Steroid Profiling of 29 Steroids Using Liquid Chromatography‐Tandem Mass Spectrometry

column for their separation. Lower limit of quantification (LLOQ) ranged from 2 to 20 ng/mL, witha ccuracy (bias) ranging from -18.7% to 19.9%, and precision (percentage coefficient of variation [%CV]) ranging from 4.0% to 18.6%. Matrix effects remained within the ideal range <±15% for all steroids. Recovery ranged from 76% to 103%, and intra- and inter-assay imprecision (CV) ranged from 0.8% to 14.9%. In 40 healthy volunteers, most analytes were detected above the LLOQ in over 95% of samples, although tetrahydro-aldosterone (85%), 5-pregenediol (68%), and pregnanetriol-one (59%) demonstrated lower quantification rates. Diurnal and sex-based variations were observed, with excretion levels significantly higher during daytime and in males. This robust, high-throughput LC-MS/MS method facilitates the simultaneous quantification of multiple steroid classes, enhancing its utility for clinical and research applications in endocrine science.

Authors

Institutions

Publication Details

Journal
Analytical Science Advances
Published
2026-04-30
DOI
https://doi.org/10.1002/ansa.70087
Primary Topic
Hormonal and reproductive studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comprehensive Quantitative Urinary Steroid Profiling of 29 Steroids Using Liquid Chromatography‐Tandem Mass Spectrometry

Lorna C Gilligan, Fozia Shaheen, Joshua Bain, Alessandro Prete et al.
Analytical Science Advances
Hormonal and reproductive studies
article

Comprehensive Quantitative Urinary Steroid Profiling of 29 Steroids Using Liquid Chromatography‐Tandem Mass Spectrometry

Lorna C Gilligan, Fozia Shaheen, Joshua Bain, Alessandro Prete, Angela E. Taylor
article en

Abstract

column for their separation. Lower limit of quantification (LLOQ) ranged from 2 to 20 ng/mL, witha ccuracy (bias) ranging from -18.7% to 19.9%, and precision (percentage coefficient of variation [%CV]) ranging from 4.0% to 18.6%. Matrix effects remained within the ideal range <±15% for all steroids. Recovery ranged from 76% to 103%, and intra- and inter-assay imprecision (CV) ranged from 0.8% to 14.9%. In 40 healthy volunteers, most analytes were detected above the LLOQ in over 95% of samples, although tetrahydro-aldosterone (85%), 5-pregenediol (68%), and pregnanetriol-one (59%) demonstrated lower quantification rates. Diurnal and sex-based variations were observed, with excretion levels significantly higher during daytime and in males. This robust, high-throughput LC-MS/MS method facilitates the simultaneous quantification of multiple steroid classes, enhancing its utility for clinical and research applications in endocrine science.

Analytical Science AdvancesVol. 7(1)
University College Birmingham (GB), NIHR Birmingham Biomedical Research Centre (GB), University of Birmingham (GB)
National Institute for Health and Care Research, Department of Health and Social Care, European Commission, Birmingham Biomedical Research Centre
Openalex Percentile: Top 13%
Hormonal and reproductive studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.