A multicenter-validated interpretable transformer model for pituitary microadenoma detection on non-contrast multiparametric MRI

BACKGROUND: Detecting pituitary microadenomas using non-contrast multi-parametric magnetic resonance imaging (MRI) is challenging yet essential for clinical decisions. This study aimed to develop a transformer deep learning (DL) model for detecting pituitary microadenomas based on non-contrast multiparametric MRI and explore the explainability techniques to enhance transparency in convolutional neural network (CNN)-based classification. The primary research question addressed is how to improve the accuracy, generalization, and interpretability of CNNs for microadenomas detection. METHODS: Non-contrast multiparametric MRI sella area scans of 590 patients were retrospectively collected from three hospitals. The development and comparison of 2D_DL, 2.5D_DL, 2D_multichannel, and transformer models for classification. By incorporating Explainable AI (XAI), including Gradient-weighted Class Activation Mapping(Grad-CAM) and SHapley Additive exPlanations (SHAP), we improve model interpretability. RESULTS: The performance of the 2D_multichannel model, with an area under the curve (AUC) of 0.893, was better to that of the 2D_T1SAG_DL, 2D_T1COR_DL, 2D_T2COR_DL (AUC, 0.884, 0.779, and 0.846, respectively). The performance of the transformer model, with an area under the curve (AUC) of 0.985, was superior to that of the 2.5D_T1SAG_DL, 2.5D_T1COR_DL, 2.5D_T2COR_DL (AUC, 0.763, 0.863, and 0.835, respectively). The non-contrast MRI-based 2.5D_DL transformer model all shows outperforming performance in the internal and two external test sets (AUC, 0.874, 0.829, and 0.819, respectively). CONCLUSIONS: Given its robust diagnostic performance and enhanced interpretability, this model demonstrates significant potential for clinical translation as a decision-support tool in the detection of pituitary microadenomas.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2026-05-02
DOI
https://doi.org/10.1186/s12880-026-02391-3
Primary Topic
Pituitary Gland Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A multicenter-validated interpretable transformer model for pituitary microadenoma detection on non-contrast multiparametric MRI

Yanli Jiang, Wenxia Yang, SiRu Kang, Jing Zhang et al.
BMC Medical Imaging
Pituitary Gland Disorders and Treatments
article

A multicenter-validated interpretable transformer model for pituitary microadenoma detection on non-contrast multiparametric MRI

Yanli Jiang, Wenxia Yang, SiRu Kang, Jing Zhang, Yijun Yu, Kai Wang, Wenhuan Yuan
article en

Abstract

BACKGROUND: Detecting pituitary microadenomas using non-contrast multi-parametric magnetic resonance imaging (MRI) is challenging yet essential for clinical decisions. This study aimed to develop a transformer deep learning (DL) model for detecting pituitary microadenomas based on non-contrast multiparametric MRI and explore the explainability techniques to enhance transparency in convolutional neural network (CNN)-based classification. The primary research question addressed is how to improve the accuracy, generalization, and interpretability of CNNs for microadenomas detection. METHODS: Non-contrast multiparametric MRI sella area scans of 590 patients were retrospectively collected from three hospitals. The development and comparison of 2D_DL, 2.5D_DL, 2D_multichannel, and transformer models for classification. By incorporating Explainable AI (XAI), including Gradient-weighted Class Activation Mapping(Grad-CAM) and SHapley Additive exPlanations (SHAP), we improve model interpretability. RESULTS: The performance of the 2D_multichannel model, with an area under the curve (AUC) of 0.893, was better to that of the 2D_T1SAG_DL, 2D_T1COR_DL, 2D_T2COR_DL (AUC, 0.884, 0.779, and 0.846, respectively). The performance of the transformer model, with an area under the curve (AUC) of 0.985, was superior to that of the 2.5D_T1SAG_DL, 2.5D_T1COR_DL, 2.5D_T2COR_DL (AUC, 0.763, 0.863, and 0.835, respectively). The non-contrast MRI-based 2.5D_DL transformer model all shows outperforming performance in the internal and two external test sets (AUC, 0.874, 0.829, and 0.819, respectively). CONCLUSIONS: Given its robust diagnostic performance and enhanced interpretability, this model demonstrates significant potential for clinical translation as a decision-support tool in the detection of pituitary microadenomas.

BMC Medical Imaging
Minzu University of China (CN), Lanzhou University of Technology (CN), The Central Hospital of Xiao gan (CN), Living Independently Now Center (US), Lanzhou University Second Hospital (CN), Lanzhou University (CN), Ministry of Industry and Information Technology (CN)
Peace, Justice and strong institutions
Openalex Percentile: Top 12%
Pituitary Gland Disorders and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.