Feasibility of using a pocket-sized ultrasound imaging device for detecting insulin-derived amyloidosis-like findings in patients with diabetes mellitus: a preliminary study.

Objectives: Insulin-derived amyloidosis (IDA) reduces insulin absorption, increasing the risk of poor glycemic control; however, early detection remains challenging. Although ultrasound can identify IDA, the effectiveness of portable pocket-sized devices has not been evaluated. This study was performed to evaluate the detectability of findings suggestive of IDA using a pocket-sized ultrasound device on the abdominal region, the most common site for stable insulin absorption in patients with diabetes mellitus. Methods: This cross-sectional observational study was conducted in the diabetes ward of a university hospital between July and December 2024. The participants were inpatients with diabetes who had been receiving insulin injections for more than 1 month. Findings suggestive of IDA were assessed through visual inspection and palpation, magnetic resonance imaging (MRI), high-performance ultrasonography, and a pocket-sized ultrasound device. The concordance rate between the pocket-sized ultrasound device and other assessment methods was calculated. Results: Of the 20 participants enrolled, 5 met the exclusion criteria; thus, data from 15 participants were included in the final analysis. Findings suggestive of IDA were identified in nine patients (60.0%) by visual inspection and palpation and in eight patients (53.3%) by the pocket-sized ultrasound device, high-performance ultrasound, and MRI. The concordance rate among the pocket-sized ultrasound device, high-performance ultrasound, and MRI was 100%, while the concordance rate between visual inspection with palpation and the pocket-sized ultrasound device was 80%. Conclusions: These findings suggest that a pocket-sized ultrasound device has the potential to detect findings suggestive of IDA and may be suitable for use in clinical practice.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2026-05-01
DOI
https://doi.org/10.20407/fmj.2025-028
Primary Topic
Amyloidosis: Diagnosis, Treatment, Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of using a pocket-sized ultrasound imaging device for detecting insulin-derived amyloidosis-like findings in patients with diabetes mellitus: a preliminary study.

Hiroji Takai, Shigeki Kobayashi, Kazuki Takano, Kimie Takehara et al.
PubMed
Amyloidosis: Diagnosis, Treatment, Outcomes
article

Feasibility of using a pocket-sized ultrasound imaging device for detecting insulin-derived amyloidosis-like findings in patients with diabetes mellitus: a preliminary study.

Hiroji Takai, Shigeki Kobayashi, Kazuki Takano, Kimie Takehara, Yasuo Takatsu, Ayano Nakai, Junko Sugama, Naoko Kageura, Atsushi Suzuki
article en

Abstract

Objectives: Insulin-derived amyloidosis (IDA) reduces insulin absorption, increasing the risk of poor glycemic control; however, early detection remains challenging. Although ultrasound can identify IDA, the effectiveness of portable pocket-sized devices has not been evaluated. This study was performed to evaluate the detectability of findings suggestive of IDA using a pocket-sized ultrasound device on the abdominal region, the most common site for stable insulin absorption in patients with diabetes mellitus. Methods: This cross-sectional observational study was conducted in the diabetes ward of a university hospital between July and December 2024. The participants were inpatients with diabetes who had been receiving insulin injections for more than 1 month. Findings suggestive of IDA were assessed through visual inspection and palpation, magnetic resonance imaging (MRI), high-performance ultrasonography, and a pocket-sized ultrasound device. The concordance rate between the pocket-sized ultrasound device and other assessment methods was calculated. Results: Of the 20 participants enrolled, 5 met the exclusion criteria; thus, data from 15 participants were included in the final analysis. Findings suggestive of IDA were identified in nine patients (60.0%) by visual inspection and palpation and in eight patients (53.3%) by the pocket-sized ultrasound device, high-performance ultrasound, and MRI. The concordance rate among the pocket-sized ultrasound device, high-performance ultrasound, and MRI was 100%, while the concordance rate between visual inspection with palpation and the pocket-sized ultrasound device was 80%. Conclusions: These findings suggest that a pocket-sized ultrasound device has the potential to detect findings suggestive of IDA and may be suitable for use in clinical practice.

PubMedVol. 12(2)
Fujita Health University (JP), Fujita Health University Hospital (JP)
Openalex Percentile: Top 11%
Amyloidosis: Diagnosis, Treatment, Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.