Calibrated Integrated Backscatter Is Associated With Increased Left Ventricular Concentricity and Left Atrial Stiffness in Resistance Trained Individuals Using Anabolic-Androgenic Steroids

Purpose: The use of Anabolic-Androgenic Steroids (AAS) is well documented in resistance trained individuals, despite reports of myocardial inflammation and fibrosis. Calibrated integrated backscatter (ciB) is an echocardiographic technique to measure ultrasonic reflectivity of the left ventricular (LV) myocardium and is a marker for tissue characterization. This study assessed ciB in both AAS using and non-using resistance trained individuals and documented any relationship to LV and left atrial (LA) structure and function. Methods: Male ( n = 120) and female ( n = 21) resistance trained individuals (age 30 ± 7 years); current (CU; n = 95) and non-users (NU; n = 46) of AAS were recruited. Comprehensive echocardiography with strain imaging was performed. ciB was measured from a parasternal long axis and LA stiffness index (E/E ′ /LA reservoir strain) and left atrioventricular coupling index (LA end-diastolic volume/LV end-diastolic volume) were calculated. Results: ciB was significantly higher in CU (–19.54 ± 4.63) than NU (–20.88 ± 3.94, p = 0.047). A significant positive correlation was observed between ciB and LV mass index (rs (139) = 0.318, p < 0.001), E/E ′ (r(138) = 0.169, p = 0.043), LA conduit strain (r(135) = –0.174, p = 0.043), LA stiffness index (rs (134) = 0.246, p = 0.004), and left atrioventricular coupling index (r(134) = 0.241, p = 0.005). ciB was not associated with any LV systolic functional parameter (global longitudinal strain or ejection fraction). Conclusions: Resistance trained individuals using AAS have significantly higher ciB than non-users, suggesting differential myocardial tissue characteristics within this population. The presence of higher levels of ciB was significantly associated with LV geometry and LV diastolic function which may indicate a role of ciB in identifying early cardiac risk in this population.

Authors

Publication Details

Journal
Hope's Institutional Research Archive (Liverpool Hope University)
Published
2026-04-10
DOI
https://doi.org/10.1111/echo.70454digital
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibrated Integrated Backscatter Is Associated With Increased Left Ventricular Concentricity and Left Atrial Stiffness in Resistance Trained Individuals Using Anabolic-Androgenic Steroids

Peter Angell, KP George, Neil Chester, H Carpenter et al.
Hope's Institutional Research Archive (Liverpool Hope University)
Cardiovascular Function and Risk Factors
article

Calibrated Integrated Backscatter Is Associated With Increased Left Ventricular Concentricity and Left Atrial Stiffness in Resistance Trained Individuals Using Anabolic-Androgenic Steroids

Peter Angell, KP George, Neil Chester, H Carpenter, R Cooper, BN Morrison, C Hamilton, LJ Howard, B Stansfield, F Pugh, D Oxborough
article en

Abstract

Purpose: The use of Anabolic-Androgenic Steroids (AAS) is well documented in resistance trained individuals, despite reports of myocardial inflammation and fibrosis. Calibrated integrated backscatter (ciB) is an echocardiographic technique to measure ultrasonic reflectivity of the left ventricular (LV) myocardium and is a marker for tissue characterization. This study assessed ciB in both AAS using and non-using resistance trained individuals and documented any relationship to LV and left atrial (LA) structure and function. Methods: Male ( n = 120) and female ( n = 21) resistance trained individuals (age 30 ± 7 years); current (CU; n = 95) and non-users (NU; n = 46) of AAS were recruited. Comprehensive echocardiography with strain imaging was performed. ciB was measured from a parasternal long axis and LA stiffness index (E/E ′ /LA reservoir strain) and left atrioventricular coupling index (LA end-diastolic volume/LV end-diastolic volume) were calculated. Results: ciB was significantly higher in CU (–19.54 ± 4.63) than NU (–20.88 ± 3.94, p = 0.047). A significant positive correlation was observed between ciB and LV mass index (rs (139) = 0.318, p < 0.001), E/E ′ (r(138) = 0.169, p = 0.043), LA conduit strain (r(135) = –0.174, p = 0.043), LA stiffness index (rs (134) = 0.246, p = 0.004), and left atrioventricular coupling index (r(134) = 0.241, p = 0.005). ciB was not associated with any LV systolic functional parameter (global longitudinal strain or ejection fraction). Conclusions: Resistance trained individuals using AAS have significantly higher ciB than non-users, suggesting differential myocardial tissue characteristics within this population. The presence of higher levels of ciB was significantly associated with LV geometry and LV diastolic function which may indicate a role of ciB in identifying early cardiac risk in this population.

Hope's Institutional Research Archive (Liverpool Hope University)
Good health and well-being
Openalex Percentile: Top 9%
Cardiovascular Function and Risk Factors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.