The impact of electric heating cape on local thermal sensation and thermal comfort of officers

This study focuses on evaluating the thermoregulatory performance of a graphene-based electric heating cape and determining its optimal temperature for use in cool indoor environments during winter. Through controlled experiments with 30 participants in a climate chamber maintained at 15.5 °C, five heating conditions (no heating, 35 °C, 40 °C, 45 °C, and 50 °C) were systematically tested. Skin temperature and heart rate were continuously monitored, and subjective thermal sensation and comfort votes were collected using 7-point scales. Results demonstrated that the electric heating cape significantly improved thermal comfort, with 40 °C identified as the optimal temperature setpoint: overall thermal sensation shifted from slightly cool to slightly warm, and overall thermal comfort state attained 'slightly comfortable' level on the adaptive comfort scale. Repeated-measures ANOVA revealed that heating temperature had a highly significant effect on both overall thermal sensation and overall thermal comfort. Post-hoc tests identified 40 °C as the optimal temperature setpoint under these environmental conditions (15.5 °C). At this temperature, the overall thermal sensation vote improved significantly from - 1.23 (no heating) to -0.13 (p < 0.01), approaching a neutral sensation, while overall thermal comfort increased significantly from - 1.08 to 0.35, reaching a "slightly comfortable" level. The most significant improvements were observed in the abdomen and lumbar regions. While skin temperature showed a positive correlation with thermal perception, heart rate remained stable (± 5 bpm), indicating a low physiological burden. Marked individual differences in temperature preference underscore the importance of personalized thermal regulation. This study provides empirical evidence to guide the application and control of localized heating devices in cool indoor office settings during winter.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-05-02
DOI
https://doi.org/10.1038/s41598-026-50983-4
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of electric heating cape on local thermal sensation and thermal comfort of officers

林上傑, Xi Meng, Yue Wang, Meng Wei et al.
Scientific Reports
Building Energy and Comfort Optimization
article

The impact of electric heating cape on local thermal sensation and thermal comfort of officers

林上傑, Xi Meng, Yue Wang, Meng Wei, Wei Mao
article en

Abstract

This study focuses on evaluating the thermoregulatory performance of a graphene-based electric heating cape and determining its optimal temperature for use in cool indoor environments during winter. Through controlled experiments with 30 participants in a climate chamber maintained at 15.5 °C, five heating conditions (no heating, 35 °C, 40 °C, 45 °C, and 50 °C) were systematically tested. Skin temperature and heart rate were continuously monitored, and subjective thermal sensation and comfort votes were collected using 7-point scales. Results demonstrated that the electric heating cape significantly improved thermal comfort, with 40 °C identified as the optimal temperature setpoint: overall thermal sensation shifted from slightly cool to slightly warm, and overall thermal comfort state attained 'slightly comfortable' level on the adaptive comfort scale. Repeated-measures ANOVA revealed that heating temperature had a highly significant effect on both overall thermal sensation and overall thermal comfort. Post-hoc tests identified 40 °C as the optimal temperature setpoint under these environmental conditions (15.5 °C). At this temperature, the overall thermal sensation vote improved significantly from - 1.23 (no heating) to -0.13 (p < 0.01), approaching a neutral sensation, while overall thermal comfort increased significantly from - 1.08 to 0.35, reaching a "slightly comfortable" level. The most significant improvements were observed in the abdomen and lumbar regions. While skin temperature showed a positive correlation with thermal perception, heart rate remained stable (± 5 bpm), indicating a low physiological burden. Marked individual differences in temperature preference underscore the importance of personalized thermal regulation. This study provides empirical evidence to guide the application and control of localized heating devices in cool indoor office settings during winter.

Scientific Reports
Qingdao University of Science and Technology (CN), Chongqing University of Technology (CN)
Climate action
Openalex Percentile: Top 14%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.