Experimental investigation of novel 18 multiturn multiplane pulsating heat pipe for methanol

A Pulsating Heat Pipe (PHP) is a wickless meandering capillary tube bent back and forth parallel to itself. In the present work, the possibility of employing a multiturn PHP as a pin-finned heat sink attached to a base plate is considered. Hence all the regions, other than those belonging to evaporators, function as condenser zones. Experimental investigations are carried on PHPs with multiturn, single plane and multiplane configurations. The condenser (or fin portions) of the PHPs is cooled by forced air flow and radiation to the surroundings. Experimental parametric runs are conducted by varying the fill ratio, orientations, and heat loads. Working fluid namely methanol is tested. PHP with 18 turns are tested for fill ratios of 30%, 50% and 70% and five orientations (+ 90°, + 45°, 0°, - 45° and - 90° measured with respect to horizontal). Heat loads are increased in steps of 50 W from 50 to 400 W for testing the PHPs. For different PHP physical geometries, the flow regimes change with respect to heat loads. The optimum angle for best thermal resistance is found to lie between 60 and 70°. Orientation independent operation observed in all the multiplane models and generally, the bottom heating mode (+ 90°) produce the highest heat transfer. During the startup, for lower heat loads, a temperature overshoot is observed before the establishment of pulsations. At higher heat loads, pulsations are set up without appreciable temperature overshoot, following a smooth startup. The results have shown enhancement in fin thermal conductivity compared to solid copper. The average thermal resistances [Formula: see text] for 18 multiplane is 0.3408 compare to dry fin thermal resistance [Formula: see text] [Formula: see text] shows its improvement in performance.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-05-02
DOI
https://doi.org/10.1038/s41598-026-41600-5
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation of novel 18 multiturn multiplane pulsating heat pipe for methanol

G S V L Narasimham, N Narendra Babu, P Srikrishna
Scientific Reports
Heat Transfer and Boiling Studies
article

Experimental investigation of novel 18 multiturn multiplane pulsating heat pipe for methanol

G S V L Narasimham, N Narendra Babu, P Srikrishna
article en

Abstract

A Pulsating Heat Pipe (PHP) is a wickless meandering capillary tube bent back and forth parallel to itself. In the present work, the possibility of employing a multiturn PHP as a pin-finned heat sink attached to a base plate is considered. Hence all the regions, other than those belonging to evaporators, function as condenser zones. Experimental investigations are carried on PHPs with multiturn, single plane and multiplane configurations. The condenser (or fin portions) of the PHPs is cooled by forced air flow and radiation to the surroundings. Experimental parametric runs are conducted by varying the fill ratio, orientations, and heat loads. Working fluid namely methanol is tested. PHP with 18 turns are tested for fill ratios of 30%, 50% and 70% and five orientations (+ 90°, + 45°, 0°, - 45° and - 90° measured with respect to horizontal). Heat loads are increased in steps of 50 W from 50 to 400 W for testing the PHPs. For different PHP physical geometries, the flow regimes change with respect to heat loads. The optimum angle for best thermal resistance is found to lie between 60 and 70°. Orientation independent operation observed in all the multiplane models and generally, the bottom heating mode (+ 90°) produce the highest heat transfer. During the startup, for lower heat loads, a temperature overshoot is observed before the establishment of pulsations. At higher heat loads, pulsations are set up without appreciable temperature overshoot, following a smooth startup. The results have shown enhancement in fin thermal conductivity compared to solid copper. The average thermal resistances [Formula: see text] for 18 multiplane is 0.3408 compare to dry fin thermal resistance [Formula: see text] [Formula: see text] shows its improvement in performance.

Scientific Reports
Defence Research and Development Organisation (IN), Microwave Tube Research & Development Centre (IN), Bristol-Myers Squibb (India) (IN), Indian Institute of Science Bangalore (IN)
Openalex Percentile: Top 14%
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental investigation of novel 18 multiturn multiplane pulsating heat pipe for methanol — G S V L Narasimham, N Narendra Babu, et al. · Scientific Reports (2026) | TGRS Research Map | TGRS