Trends in accuracy management of continuous glucose monitoring systems

Continuous glucose monitoring (CGM) has markedly advanced diabetes care by enabling real-time visualization of glycaemic variability, prevention of hypoglycaemia, and direct integration into therapeutic decision-making. As CGM use expands in routine practice and automated insulin delivery systems, however, accuracy has become a critical determinant of treatment safety. This mini-review summarizes recent advances in CGM accuracy management across three major driving forces: (1) accelerating technological innovation, including multi-analyte sensors, non-invasive devices, and artificial intelligence (AI)-based signal processing; (2) systematization and international harmonization of regulatory accuracy frameworks, exemplified by U.S. Food and Drug Administration (FDA) integrated CGM (iCGM) and the proposed CGM in Europe (eCGM) concept; and (3) growing societal demands for transparency, including public disclosure of performance data and strengthened lot-to-lot evaluation. We outline the four key dimensions of CGM accuracy-analytical accuracy, clinical accuracy, trend accuracy, and precision. We then review the evolution of regional accuracy standards, focusing on highly influential frameworks in the United States and Europe. Key considerations in accuracy-study design are discussed, along with clinical risks associated with reduced accuracy optimization, and progress toward global standardization. Finally, we examine future directions in the era of next-generation technologies, such as multi-analyte and non-invasive sensors, AI-driven accuracy optimization, and progress toward international standardization. This review provides an overview of the current landscape and future directions of CGM accuracy management in an era where fluctuations in accuracy directly affect treatment safety. We aim to clarify the perspectives required in both clinical practice and research to ensure safe and effective use of CGM.

Authors

Institutions

Publication Details

Journal
Diabetology International
Published
2026-04-30
DOI
https://doi.org/10.1007/s13340-026-00901-w
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Trends in accuracy management of continuous glucose monitoring systems

Keiichi Torimoto, Yosuke Okada
Diabetology International
Diabetes Management and Research
article

Trends in accuracy management of continuous glucose monitoring systems

Keiichi Torimoto, Yosuke Okada
article en

Abstract

Continuous glucose monitoring (CGM) has markedly advanced diabetes care by enabling real-time visualization of glycaemic variability, prevention of hypoglycaemia, and direct integration into therapeutic decision-making. As CGM use expands in routine practice and automated insulin delivery systems, however, accuracy has become a critical determinant of treatment safety. This mini-review summarizes recent advances in CGM accuracy management across three major driving forces: (1) accelerating technological innovation, including multi-analyte sensors, non-invasive devices, and artificial intelligence (AI)-based signal processing; (2) systematization and international harmonization of regulatory accuracy frameworks, exemplified by U.S. Food and Drug Administration (FDA) integrated CGM (iCGM) and the proposed CGM in Europe (eCGM) concept; and (3) growing societal demands for transparency, including public disclosure of performance data and strengthened lot-to-lot evaluation. We outline the four key dimensions of CGM accuracy-analytical accuracy, clinical accuracy, trend accuracy, and precision. We then review the evolution of regional accuracy standards, focusing on highly influential frameworks in the United States and Europe. Key considerations in accuracy-study design are discussed, along with clinical risks associated with reduced accuracy optimization, and progress toward global standardization. Finally, we examine future directions in the era of next-generation technologies, such as multi-analyte and non-invasive sensors, AI-driven accuracy optimization, and progress toward international standardization. This review provides an overview of the current landscape and future directions of CGM accuracy management in an era where fluctuations in accuracy directly affect treatment safety. We aim to clarify the perspectives required in both clinical practice and research to ensure safe and effective use of CGM.

Diabetology InternationalVol. 17(3)
University of Occupational and Environmental Health Japan (JP)
Zero hunger
Openalex Percentile: Top 11%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Trends in accuracy management of continuous glucose monitoring systems — Keiichi Torimoto, Yosuke Okada · Diabetology International (2026) | TGRS Research Map | TGRS