Patient-Related Factors Associated with Mechanical Failure After Hemilaminectomy with Posterolateral Fusion: An Exploratory Retrospective Cohort Study

Background: Implant-related mechanical failure remains a clinically relevant concern following posterior decompression and fusion in elderly patients with lumbar spinal stenosis (LSS). The relative contribution of host-related versus construct-related factors to failure risk requires further clarification. Methods: This retrospective single-center cohort study included 118 patients aged ≥65 years who underwent single-level hemilaminectomy with posterolateral fusion (PLF) for isolated L4–5 central LSS, with a minimum follow-up of 48 months (mean 51.0 ± 2.0 months). All procedures were performed using a standardized posterior technique with uniform 6.5-mm titanium rods and 6.5-mm pedicle screws. Mechanical failure was defined as revision surgery due to radiographically and clinically confirmed hardware-related complications in the absence of infection. Exploratory univariable analyses were conducted to evaluate associations between baseline variables and mechanical failure. Clinical outcomes were assessed using validated patient-reported outcome measures. The Oswestry Disability Index (ODI), Roland Morris Disability Questionnaire (RMDQ), and Visual Analog Scale (VAS) for pain were recorded. Results: Overall revision rate was 13.6% (16/118), including 14 cases (11.9%) of implant-related mechanical failure and 2 cases (1.7%) of infection-related revision. Higher age (p = 0.005), higher body mass index (BMI) (p = 0.005), lower bone mineral density (BMD) (p < 0.001), active smoking (p < 0.001), and diabetes mellitus (DM) (p = 0.023) were significantly associated with mechanical failure. Functional outcomes (ODI, RMDQ, VAS) improved significantly at final follow-up (all p < 0.001). Conclusions: Mechanical failure following hemilaminectomy with PLF appears to be predominantly influenced by host-related factors rather than construct characteristics when a standardized surgical technique is applied. Bone quality and modifiable systemic risk factors may play a critical role in long-term construct durability.

Authors

Institutions

Publication Details

Journal
Healthcare
Published
2026-04-29
DOI
https://doi.org/10.3390/healthcare14091199
Primary Topic
Spine and Intervertebral Disc Pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patient-Related Factors Associated with Mechanical Failure After Hemilaminectomy with Posterolateral Fusion: An Exploratory Retrospective Cohort Study

Evren Karaali, burak keklikçioğlu, Fırat Seyfettinoğlu, Hakan Uslu et al.
Healthcare
Spine and Intervertebral Disc Pathology
article

Patient-Related Factors Associated with Mechanical Failure After Hemilaminectomy with Posterolateral Fusion: An Exploratory Retrospective Cohort Study

Evren Karaali, burak keklikçioğlu, Fırat Seyfettinoğlu, Hakan Uslu, Oğuzhan Çiçek, Ziya Çay, İsmail Akçay, Osman Çiloğlu
article en

Abstract

Background: Implant-related mechanical failure remains a clinically relevant concern following posterior decompression and fusion in elderly patients with lumbar spinal stenosis (LSS). The relative contribution of host-related versus construct-related factors to failure risk requires further clarification. Methods: This retrospective single-center cohort study included 118 patients aged ≥65 years who underwent single-level hemilaminectomy with posterolateral fusion (PLF) for isolated L4–5 central LSS, with a minimum follow-up of 48 months (mean 51.0 ± 2.0 months). All procedures were performed using a standardized posterior technique with uniform 6.5-mm titanium rods and 6.5-mm pedicle screws. Mechanical failure was defined as revision surgery due to radiographically and clinically confirmed hardware-related complications in the absence of infection. Exploratory univariable analyses were conducted to evaluate associations between baseline variables and mechanical failure. Clinical outcomes were assessed using validated patient-reported outcome measures. The Oswestry Disability Index (ODI), Roland Morris Disability Questionnaire (RMDQ), and Visual Analog Scale (VAS) for pain were recorded. Results: Overall revision rate was 13.6% (16/118), including 14 cases (11.9%) of implant-related mechanical failure and 2 cases (1.7%) of infection-related revision. Higher age (p = 0.005), higher body mass index (BMI) (p = 0.005), lower bone mineral density (BMD) (p < 0.001), active smoking (p < 0.001), and diabetes mellitus (DM) (p = 0.023) were significantly associated with mechanical failure. Functional outcomes (ODI, RMDQ, VAS) improved significantly at final follow-up (all p < 0.001). Conclusions: Mechanical failure following hemilaminectomy with PLF appears to be predominantly influenced by host-related factors rather than construct characteristics when a standardized surgical technique is applied. Bone quality and modifiable systemic risk factors may play a critical role in long-term construct durability.

HealthcareVol. 14(9)
Sağlık Bilimleri Üniversitesi (TR)
Good health and well-being
Openalex Percentile: Top 10%
Spine and Intervertebral Disc Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.