MitraNav: Design and Modeling of a Robotic System for Transseptal Mitral Valve Replacement with Dock Catheter Task-Space Control

PURPOSE: Transcatheter mitral valve replacement (TMVR) is a promising therapy for reducing mitral regurgitation in select patients. Direct tip control of multi-segment catheters can simplify manipulation and enable precise, stable positioning. This paper introduces MitraNav, the first robotic system developed for dock-based TMVR, focusing on system design and task-space control of the dock catheter. METHODS: Built on a previously validated guide-sheath robot, MitraNav is upgraded to support concentric multi-catheter manipulation via a unified actuation mechanism. It suits both dock and balloon catheters, enabling all catheter manipulation using a single robotic system. A two-segment bending model maps joint space to task space through an intermediate configuration space. A two-stage control strategy is then applied: joint-space control allows for rapid approach to the mitral annulus, followed by task-space control for direct tip positioning. To improve accuracy and handle joint limits, the task-space controller incorporates Jacobian normalization to balance joint contributions, null-space optimization to regulate joint motion without affecting the primary task, and a PD controller to reduce tracking errors. RESULTS: Trajectory-following experiments demonstrate feasibility of direct tip control, with maximum errors of 2.38 mm, 2.53 mm, and 2.46 mm in three trials. These positional errors are within the range of acceptable accuracy commonly considered for catheter-based cardiac interventions. CONCLUSION: MitraNav represents the foundation for intuitive catheter manipulation and offers the potential for semi-autonomous robotic dock-based TMVR.

Authors

Institutions

Publication Details

Journal
Annals of Biomedical Engineering
Published
2026-05-02
DOI
https://doi.org/10.1007/s10439-026-04154-1
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MitraNav: Design and Modeling of a Robotic System for Transseptal Mitral Valve Replacement with Dock Catheter Task-Space Control

Kawal Rhode, R. James Housden, Weizhao Wang, S Wang et al.
Annals of Biomedical Engineering
Soft Robotics and Applications
article

MitraNav: Design and Modeling of a Robotic System for Transseptal Mitral Valve Replacement with Dock Catheter Task-Space Control

Kawal Rhode, R. James Housden, Weizhao Wang, S Wang, Jiyu Cai, Zhenguan Tu
article en

Abstract

PURPOSE: Transcatheter mitral valve replacement (TMVR) is a promising therapy for reducing mitral regurgitation in select patients. Direct tip control of multi-segment catheters can simplify manipulation and enable precise, stable positioning. This paper introduces MitraNav, the first robotic system developed for dock-based TMVR, focusing on system design and task-space control of the dock catheter. METHODS: Built on a previously validated guide-sheath robot, MitraNav is upgraded to support concentric multi-catheter manipulation via a unified actuation mechanism. It suits both dock and balloon catheters, enabling all catheter manipulation using a single robotic system. A two-segment bending model maps joint space to task space through an intermediate configuration space. A two-stage control strategy is then applied: joint-space control allows for rapid approach to the mitral annulus, followed by task-space control for direct tip positioning. To improve accuracy and handle joint limits, the task-space controller incorporates Jacobian normalization to balance joint contributions, null-space optimization to regulate joint motion without affecting the primary task, and a PD controller to reduce tracking errors. RESULTS: Trajectory-following experiments demonstrate feasibility of direct tip control, with maximum errors of 2.38 mm, 2.53 mm, and 2.46 mm in three trials. These positional errors are within the range of acceptable accuracy commonly considered for catheter-based cardiac interventions. CONCLUSION: MitraNav represents the foundation for intuitive catheter manipulation and offers the potential for semi-autonomous robotic dock-based TMVR.

Annals of Biomedical Engineering
King's College London (GB), Chinese Academy of Sciences (CN), Hong Kong Science and Technology Parks Corporation (HK), Shandong Institute of Automation (CN), Beijing Academy of Artificial Intelligence (CN)
China Scholarship Council, Centre For Medical Engineering, King’s College London
Openalex Percentile: Top 13%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.