A Retrospective Study: Comparative Visual Performance of Two Non-Diffractive Extended Depth-of-Focus Intraocular Lenses: TECNIS PureSee versus Clareon Vivity

Junha Kang,1,* Jeewon Han,2,* Chung Min Lee,2 Nahyun Park,2 Yea Eun Lee,2 Kyu Sang Eah,2 Ho Seok Chung,2 Jae Yong Kim,2 Ronald Yeoh,3 Hyeck-Soo Son,4 Hun Lee2,5 1City St George’s, University of London, London, UK; 2Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea; 3Singapore National Eye Centre, Singapore; 4Department of Ophthalmology, University of Heidelberg, Heidelberg, Baden-Wuerttemberg, Germany; 5Brain Korea 21 Project, Department of Ophthalmology, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea*These authors contributed equally to this workCorrespondence: Hun Lee, Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea, Email [email protected]: To compare postoperative visual performance between two non-diffractive, extended depth-of-focus (EDoF) intraocular lenses (IOLs) — TECNIS PureSee and Clareon Vivity — by evaluating visual acuity, contrast sensitivity, and patient-reported outcomes.Methods: In this retrospective comparative study, 102 eyes (51 per group) received either the PureSee or Vivity IOL. Visual acuity at various distances, defocus curves, and contrast sensitivity under photopic and mesopic conditions were assessed at 2 months postoperatively. Patient satisfaction and visual disturbances were also evaluated.Results: Both the PureSee and Vivity IOL demonstrated comparable visual acuity at far and near distances, while the Vivity showing significantly better visual acuity at intermediate distances (P = 0.045). Contrast sensitivity was significantly higher in the PureSee group at higher spatial frequencies (P = 0.038). Patient satisfaction and spectacle independence were high and comparable in both groups. The Vivity group showed a trend toward fewer reports of glare and halo.Conclusion: The Vivity IOL performed better at intermediate distances with fewer photic phenomena when compared with the PureSee IOL. The differences between these two EDoF IOLs may help in lens selection based on patient’s visual demands and lifestyle.Keywords: extended depth-of-focus IOLs, cataract surgery, TECNIS PureSee, Clareon Vivity

Authors

Institutions

Publication Details

Journal
DOAJ (DOAJ: Directory of Open Access Journals)
Published
2026-05-01
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Retrospective Study: Comparative Visual Performance of Two Non-Diffractive Extended Depth-of-Focus Intraocular Lenses: TECNIS PureSee versus Clareon Vivity

Kim Jy, Park N, Son HS, Eah KS et al.
DOAJ (DOAJ: Directory of Open Access Journals)
Ophthalmology and Visual Impairment Studies
article

A Retrospective Study: Comparative Visual Performance of Two Non-Diffractive Extended Depth-of-Focus Intraocular Lenses: TECNIS PureSee versus Clareon Vivity

Kim Jy, Park N, Son HS, Eah KS, Lee YE, Lee H, Kang J, Yeoh R, Han J, Lee CM, Chung HS
article en

Abstract

Junha Kang,1,* Jeewon Han,2,* Chung Min Lee,2 Nahyun Park,2 Yea Eun Lee,2 Kyu Sang Eah,2 Ho Seok Chung,2 Jae Yong Kim,2 Ronald Yeoh,3 Hyeck-Soo Son,4 Hun Lee2,5 1City St George’s, University of London, London, UK; 2Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea; 3Singapore National Eye Centre, Singapore; 4Department of Ophthalmology, University of Heidelberg, Heidelberg, Baden-Wuerttemberg, Germany; 5Brain Korea 21 Project, Department of Ophthalmology, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea*These authors contributed equally to this workCorrespondence: Hun Lee, Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea, Email [email protected]: To compare postoperative visual performance between two non-diffractive, extended depth-of-focus (EDoF) intraocular lenses (IOLs) — TECNIS PureSee and Clareon Vivity — by evaluating visual acuity, contrast sensitivity, and patient-reported outcomes.Methods: In this retrospective comparative study, 102 eyes (51 per group) received either the PureSee or Vivity IOL. Visual acuity at various distances, defocus curves, and contrast sensitivity under photopic and mesopic conditions were assessed at 2 months postoperatively. Patient satisfaction and visual disturbances were also evaluated.Results: Both the PureSee and Vivity IOL demonstrated comparable visual acuity at far and near distances, while the Vivity showing significantly better visual acuity at intermediate distances (P = 0.045). Contrast sensitivity was significantly higher in the PureSee group at higher spatial frequencies (P = 0.038). Patient satisfaction and spectacle independence were high and comparable in both groups. The Vivity group showed a trend toward fewer reports of glare and halo.Conclusion: The Vivity IOL performed better at intermediate distances with fewer photic phenomena when compared with the PureSee IOL. The differences between these two EDoF IOLs may help in lens selection based on patient’s visual demands and lifestyle.Keywords: extended depth-of-focus IOLs, cataract surgery, TECNIS PureSee, Clareon Vivity

DOAJ (DOAJ: Directory of Open Access Journals)
Cataract Foundation of the Philippines (PH)
Openalex Percentile: Top 13%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.