Real-Time Gait Analysis of the Pelvis and Lower Limbs Using a Seven-Node IMU Network

To address limited segment coverage and integration drift in wearable inertial gait analysis, this work proposes a real-time multi-segment gait analysis method using seven MEMS-IMUs deployed on the pelvis and lower limbs. The method employs parameter adaptive nonlinear complementary filtering and foot-based event detection to calculate spatiotemporal parameters and joint angles. Validation against optical motion capture (OMC) showed sagittal joint angle RMSEs below 2.37°, pelvic angle RMSEs below 0.96°, and correlation coefficients above 0.89 during normal walking in healthy adults. Supported by real-time 3D skeletal visualization, the proposed system provides a low-cost and portable solution for quantitative gait assessment under controlled walking conditions, with potential for future rehabilitation monitoring after further clinical validation.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-04-29
DOI
https://doi.org/10.3390/s26092776
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Gait Analysis of the Pelvis and Lower Limbs Using a Seven-Node IMU Network

Enlin Cai, Shuying Wang, Liangyang Luo, Xiao Wang et al.
Sensors
Balance, Gait, and Falls Prevention
article

Real-Time Gait Analysis of the Pelvis and Lower Limbs Using a Seven-Node IMU Network

Enlin Cai, Shuying Wang, Liangyang Luo, Xiao Wang, Lin Wang
article en

Abstract

To address limited segment coverage and integration drift in wearable inertial gait analysis, this work proposes a real-time multi-segment gait analysis method using seven MEMS-IMUs deployed on the pelvis and lower limbs. The method employs parameter adaptive nonlinear complementary filtering and foot-based event detection to calculate spatiotemporal parameters and joint angles. Validation against optical motion capture (OMC) showed sagittal joint angle RMSEs below 2.37°, pelvic angle RMSEs below 0.96°, and correlation coefficients above 0.89 during normal walking in healthy adults. Supported by real-time 3D skeletal visualization, the proposed system provides a low-cost and portable solution for quantitative gait assessment under controlled walking conditions, with potential for future rehabilitation monitoring after further clinical validation.

SensorsVol. 26(9)
Qingdao University (CN), University of Jinan (CN)
Good health and well-being
Openalex Percentile: Top 6%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.