Diagnostic Impact of Two‐Dimensional Shear Wave Elastography for Liver Fibrosis: A Multicenter Retrospective Study

AIM: Two-dimensional shear wave elastography (2D-SWE) is a non-invasive technique for assessing liver fibrosis. However, its clinical utility has not been fully established. This study evaluated the diagnostic accuracy of 2D-SWE using magnetic resonance elastography (MRE) as the reference standard in a retrospective, multicenter, large-scale cohort. METHODS: A total of 744 patients with chronic liver disease were included in the analysis. The association between 2D-SWE measurements and fibrosis stages determined by MRE was assessed. The correlation between 2D-SWE and MRE values was analyzed, and the diagnostic performance of 2D-SWE was evaluated using receiver operating characteristic (ROC) curve analysis. RESULTS: As 2D-SWE and MRE values were not normally distributed, they were log-transformed (Log-2D-SWE and Log-MRE) for analysis. A strong correlation was observed between Log-2D-SWE and Log-MRE values, with a correlation coefficient of 0.764 (p < 0.001). When 2D-SWE values were stratified according to the histological stages of liver fibrosis (F0-F4), based on MRE data, the corresponding median values were 4.61, 5.63, 6.18, 7.44, and 11.64 kPa, respectively (p < 0.001, Jonckheere-Terpstra test). The areas under the ROC curve (AUROCs) and cutoff values for 2D-SWE were 0.872 and 5.47 kPa for ≥ F1 (n = 285), 0.894 and 5.88 kPa for ≥ F2 (n = 217), 0.931 and 6.48 kPa for ≥ F3 (n = 137), and 0.937 and 7.39 kPa for F4 (n = 81), respectively. In subgroup analyses, AUROCs for detecting ≥ F2, ≥F3, and F4 exceeded 0.78, even among patients with elevated body mass index or advanced hepatic steatosis. CONCLUSIONS: 2D-SWE represents a highly useful and reliable non-invasive modality for assessing of liver fibrosis.

Authors

Institutions

Publication Details

Journal
Hepatology Research
Published
2026-05-01
DOI
https://doi.org/10.1111/hepr.70194
Primary Topic
Liver Disease Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Impact of Two‐Dimensional Shear Wave Elastography for Liver Fibrosis: A Multicenter Retrospective Study

Tamami Abe, Reiichiro Kondo, Junko Tanaka, F MORIYASU et al.
Hepatology Research
Liver Disease Diagnosis and Treatment
article

Diagnostic Impact of Two‐Dimensional Shear Wave Elastography for Liver Fibrosis: A Multicenter Retrospective Study

Tamami Abe, Reiichiro Kondo, Junko Tanaka, F MORIYASU, Shigehiro Kokubu, Asako Nogami, Sadanobu Ogawa, Takuma Nakatsuka, Yuichiro Eguchi, Atsushi Nakajima, Yasuaki Suzuki, Masashi Hirooka, Hiroko Iijima, Yoichi Hiasa, Masayoshi Kage, Ryosuke Tateishi, Hidekatsu Kuroda, Tomoyuki Akita, Hidenori Toyoda, Hirohisa Yano, Kento Imajo, Hirokazu Takahashi, Takashi Kumada, Satoshi Oeda, Takashi Nishimura, Toshifumi Tada, Katsutoshi Sugimoto
article en

Abstract

AIM: Two-dimensional shear wave elastography (2D-SWE) is a non-invasive technique for assessing liver fibrosis. However, its clinical utility has not been fully established. This study evaluated the diagnostic accuracy of 2D-SWE using magnetic resonance elastography (MRE) as the reference standard in a retrospective, multicenter, large-scale cohort. METHODS: A total of 744 patients with chronic liver disease were included in the analysis. The association between 2D-SWE measurements and fibrosis stages determined by MRE was assessed. The correlation between 2D-SWE and MRE values was analyzed, and the diagnostic performance of 2D-SWE was evaluated using receiver operating characteristic (ROC) curve analysis. RESULTS: As 2D-SWE and MRE values were not normally distributed, they were log-transformed (Log-2D-SWE and Log-MRE) for analysis. A strong correlation was observed between Log-2D-SWE and Log-MRE values, with a correlation coefficient of 0.764 (p < 0.001). When 2D-SWE values were stratified according to the histological stages of liver fibrosis (F0-F4), based on MRE data, the corresponding median values were 4.61, 5.63, 6.18, 7.44, and 11.64 kPa, respectively (p < 0.001, Jonckheere-Terpstra test). The areas under the ROC curve (AUROCs) and cutoff values for 2D-SWE were 0.872 and 5.47 kPa for ≥ F1 (n = 285), 0.894 and 5.88 kPa for ≥ F2 (n = 217), 0.931 and 6.48 kPa for ≥ F3 (n = 137), and 0.937 and 7.39 kPa for F4 (n = 81), respectively. In subgroup analyses, AUROCs for detecting ≥ F2, ≥F3, and F4 exceeded 0.78, even among patients with elevated body mass index or advanced hepatic steatosis. CONCLUSIONS: 2D-SWE represents a highly useful and reliable non-invasive modality for assessing of liver fibrosis.

Hepatology Research
Kurume University (JP), Hiroshima University (JP), Hyogo Medical University (JP), Tokyo Medical University (JP), Saga University (JP), Iwate Medical University (JP), Ehime Medical Center (JP), University of Tokyo Hospital (JP), Nayoro City General Hospital (JP), Fukui-ken Saiseikai Hospital (JP), Ogaki Municipal Hospital (JP), Himeji Red Cross Hospital (JP), Saiseikai Fukuoka General Hospital (JP), Hyogo Prefectural Nishinomiya Hospital (JP), Midorigaoka Hospital (JP), Ehime University (JP), Gifu Kyoritsu University (JP), Kobe University (JP), Yokohama City University (JP)
Canon Medical Systems Corporation
Openalex Percentile: Top 13%
Liver Disease Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.