Value of CT in quantitatively diagnosing and assessing collapse in patients with femoral head necrosis based on finite element mechanics analysis

BACKGROUND: Mechanical analysis of the femoral head is mostly conducted through finite element analysis (FEA), the operation of which is relatively complex. In this study, the correlation between computed tomography (CT) quantitative analysis and FEA in the diagnosis of osteonecrosis of the femoral head (ONFH) was analyzed. METHODS: This retrospective study involved 30 hips from patients with Steinberg stage II ONFH who had not received treatment. The average CT density was measured, and an FEA model was constructed on the basis of the CT images of each case. The correlation between the average CT density and the FEA measurements was analyzed. RESULTS: The average CT density of the coronal midline plane was 370.47 ± 16.85 HU, and that of the maximum necrotic layer was 420.73 ± 22.24 HU. According to the FEA results, the maximum total displacement was 0.42 ± 0.04 mm, the maximum displacement in the Z direction was 0.25 ± 0.02 mm, the maximum equivalent stress in the stress concentration zone of the head was 1.81 ± 0.02 MPa, and the failure coefficient was 0.34 ± 0.02. The average CT density of the maximum necrotic layer was not correlated with the maximum total displacement or maximum displacement in the Z direction but was correlated with the maximum equivalent stress (r = 0.65; P < 0.1001) and failure coefficient (r=-0.58; P < 0.001). The average CT intensity of the maximum slice (P = 0.004) and the average failure coefficient (P = 0.020) significantly differed between the collapse and noncollapse groups. CONCLUSION: CT quantification can reflect the load distribution and bearing capacity of ONFH to some extent. The higher the average CT density of the maximum slice, the lower are the average failure coefficient of the femoral head and the clinical risk of collapse.

Authors

Institutions

Publication Details

Journal
BMC Musculoskeletal Disorders
Published
2026-05-02
DOI
https://doi.org/10.1186/s12891-026-09913-8
Primary Topic
Bone and Joint Diseases
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Value of CT in quantitatively diagnosing and assessing collapse in patients with femoral head necrosis based on finite element mechanics analysis

谢利民, Zhixiu Hao, Zhennan Zhang, Zhihai Zhang et al.
BMC Musculoskeletal Disorders
Bone and Joint Diseases
article

Value of CT in quantitatively diagnosing and assessing collapse in patients with femoral head necrosis based on finite element mechanics analysis

谢利民, Zhixiu Hao, Zhennan Zhang, Zhihai Zhang, Xin Li, Shan Shi, You Zhou, Tong Yu, Wenjuan Tan
article en

Abstract

BACKGROUND: Mechanical analysis of the femoral head is mostly conducted through finite element analysis (FEA), the operation of which is relatively complex. In this study, the correlation between computed tomography (CT) quantitative analysis and FEA in the diagnosis of osteonecrosis of the femoral head (ONFH) was analyzed. METHODS: This retrospective study involved 30 hips from patients with Steinberg stage II ONFH who had not received treatment. The average CT density was measured, and an FEA model was constructed on the basis of the CT images of each case. The correlation between the average CT density and the FEA measurements was analyzed. RESULTS: The average CT density of the coronal midline plane was 370.47 ± 16.85 HU, and that of the maximum necrotic layer was 420.73 ± 22.24 HU. According to the FEA results, the maximum total displacement was 0.42 ± 0.04 mm, the maximum displacement in the Z direction was 0.25 ± 0.02 mm, the maximum equivalent stress in the stress concentration zone of the head was 1.81 ± 0.02 MPa, and the failure coefficient was 0.34 ± 0.02. The average CT density of the maximum necrotic layer was not correlated with the maximum total displacement or maximum displacement in the Z direction but was correlated with the maximum equivalent stress (r = 0.65; P < 0.1001) and failure coefficient (r=-0.58; P < 0.001). The average CT intensity of the maximum slice (P = 0.004) and the average failure coefficient (P = 0.020) significantly differed between the collapse and noncollapse groups. CONCLUSION: CT quantification can reflect the load distribution and bearing capacity of ONFH to some extent. The higher the average CT density of the maximum slice, the lower are the average failure coefficient of the femoral head and the clinical risk of collapse.

BMC Musculoskeletal Disorders
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Guang’anmen Hospital (CN), Tsinghua University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 9%
Bone and Joint Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.