Post-Curing Duration on the Mechanical Performance and Surface Quality of LCD-Printed Denture Base Resin
Objective: To investigated how post-curing times of 10 minutes and 20 minutes affect the mechanical properties and surface characteristics of LCD-printed denture base resin. Materials and Methods: Ninety standardized specimens were fabricated and distributed across three experimental groups consisting of an untreated control sample and two groups that received post-curing treatments for 10 minutes and 20 minutes. The three-point bending test evaluated flexural strength through its testing procedure. Vickers microhardness testing in a microhardness indenter was used to measure hardness while digital profilometry assessed surface roughness. Results: A trend for improved mechanical properties were observed with extended post-curing time although not statistically different. Conclusion: The mechanical strength of 3D-printed denture base resins may increase with longer post-curing times, but this method prevents damage to the surface.
Authors
- Ahmed Al–Ali
- Nooralhouda Saadallah Alhamdani
Publication Details
- Journal
- Dentistry 3000
- Published
- 2026-04-30
- DOI
- https://doi.org/10.5195/d3000.2026.1274
- Primary Topic
- Dental materials and restorations
- Type
- article
- Field-Weighted Citation Impact
- 0.00