Effects of Endotracheal Suctioning With Expiratory Pause in Infants

BACKGROUND: Endotracheal suctioning is a routine procedure in the pediatric ICU (PICU) and can be performed via open or closed systems. Closed-system suctioning has benefits for pressure maintenance in the ventilatory system and oxygen supply during the technique but is less effective. The association of an expiratory pause in closed-system suctioning is an alternative technique. We sought to evaluate the volume of suctioned secretions, respiratory mechanics, and hemodynamic parameters during closed endotracheal suctioning with expiratory pause, compared with conventional closed suctioning. METHODS: Randomized crossover pilot trial with infants receiving invasive mechanical ventilation >24 h, with neuromuscular blocker, without cough reflex, randomized to define the order of suctioning techniques (T1-technique 1 conventional suctioning without expiratory pause; T2-technique 2: with expiratory pause), performed with a 2-h interval. Evaluated hemodynamic parameters (heart rate, blood pressure, and peripheral arterial oxygen saturation), respiratory mechanics (static and dynamic compliance, inspiratory and expiratory resistance, driving pressure), and suctioning secretion were weighed on a precision balance. Shapiro-Wilk test for normally distributed variables analysis and generalized estimating equation for effect analysis. RESULTS: = .02), with an increase in these variables after suctioning with expiratory pause. There were no significant differences in hemodynamic variables. CONCLUSIONS: The closed-system suctioning with expiratory pause was more effective in secretion removal compared with conventional closed suctioning. However, driving pressure and inspiratory resistance increased after suctioning with an expiratory pause.

Authors

Institutions

Publication Details

Journal
Respiratory Care
Published
2026-05-02
DOI
https://doi.org/10.1177/19433654261427697
Primary Topic
Nosocomial Infections in ICU
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Endotracheal Suctioning With Expiratory Pause in Infants

Bruna Ziegler, Camila Wohlgemuth Schaan, Taila Cristina Piva, Ana Paula Dattein Peiter et al.
Respiratory Care
Nosocomial Infections in ICU
article

Effects of Endotracheal Suctioning With Expiratory Pause in Infants

Bruna Ziegler, Camila Wohlgemuth Schaan, Taila Cristina Piva, Ana Paula Dattein Peiter, Francisco Bruno, Cinara Andreolio, Taciana Fassbinder Piccoli
article en

Abstract

BACKGROUND: Endotracheal suctioning is a routine procedure in the pediatric ICU (PICU) and can be performed via open or closed systems. Closed-system suctioning has benefits for pressure maintenance in the ventilatory system and oxygen supply during the technique but is less effective. The association of an expiratory pause in closed-system suctioning is an alternative technique. We sought to evaluate the volume of suctioned secretions, respiratory mechanics, and hemodynamic parameters during closed endotracheal suctioning with expiratory pause, compared with conventional closed suctioning. METHODS: Randomized crossover pilot trial with infants receiving invasive mechanical ventilation >24 h, with neuromuscular blocker, without cough reflex, randomized to define the order of suctioning techniques (T1-technique 1 conventional suctioning without expiratory pause; T2-technique 2: with expiratory pause), performed with a 2-h interval. Evaluated hemodynamic parameters (heart rate, blood pressure, and peripheral arterial oxygen saturation), respiratory mechanics (static and dynamic compliance, inspiratory and expiratory resistance, driving pressure), and suctioning secretion were weighed on a precision balance. Shapiro-Wilk test for normally distributed variables analysis and generalized estimating equation for effect analysis. RESULTS: = .02), with an increase in these variables after suctioning with expiratory pause. There were no significant differences in hemodynamic variables. CONCLUSIONS: The closed-system suctioning with expiratory pause was more effective in secretion removal compared with conventional closed suctioning. However, driving pressure and inspiratory resistance increased after suctioning with an expiratory pause.

Respiratory Care
Universidade Federal do Rio Grande do Sul (BR), Hospital de Clínicas de Porto Alegre (BR), Hospital Nossa Senhora da Conceição (BR), Grupo Hospitalar Conceição (BR), Hospital de Clínicas (UY)
Good health and well-being
Openalex Percentile: Top 11%
Nosocomial Infections in ICU
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.