Optimizing transducer choice for the detection of alveolar–interstitial syndrome in dogs and cats: an evidence-based review

Alveolar–interstitial syndrome (AIS) is a common ultrasonographic finding in dogs and cats with pulmonary pathology, including cardiogenic pulmonary edema, noncardiogenic pulmonary edema, pneumonia, acute respiratory distress syndrome, and pulmonary contusion. Point-of-care lung ultrasound (LUS) has emerged as a rapid, noninvasive, and repeatable diagnostic tool for identifying AIS in emergency and critical care patients. Despite its increasing clinical adoption, transducer selection remains largely operator-dependent, with limited evidence-based guidance for veterinary applications. This review synthesizes current veterinary and human literature to evaluate how transducer type influences the detection and characterization of AIS in small animals. The acoustic properties, field of view, penetration depth, and resolution trade-offs of linear, curvilinear, and microconvex transducers are discussed in relation to B-line visualization, pleural line assessment, and detection of subpleural consolidations. Comparative performance data, including the results of recent veterinary studies, are integrated to highlight differences in diagnostic sensitivity, specificity, and interobserver reliability. A clinical decision-making framework is proposed, outlining optimal transducer selection by patient size, suspected pathology, and clinical context (triage, monitoring, follow-up). Practical considerations such as transducer availability, equipment ergonomics, and operator training are addressed. Knowledge gaps and future research priorities, including the role of portable devices and AI-assisted image interpretation, are identified. By consolidating the available evidence, this review aims to standardize and optimize transducer selection in veterinary lung ultrasound, improving diagnostic accuracy, accelerating clinical decision-making, and ultimately enhancing patient outcomes in small animal emergency and critical care.

Authors

Institutions

Publication Details

Journal
Frontiers in Veterinary Science
Published
2026-04-30
DOI
https://doi.org/10.3389/fvets.2026.1778331
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing transducer choice for the detection of alveolar–interstitial syndrome in dogs and cats: an evidence-based review

Kyle L. Granger, Charles T. Talbot, Cody I. Riffe, Søren R. Boysen
Frontiers in Veterinary Science
Ultrasound in Clinical Applications
article

Optimizing transducer choice for the detection of alveolar–interstitial syndrome in dogs and cats: an evidence-based review

Kyle L. Granger, Charles T. Talbot, Cody I. Riffe, Søren R. Boysen
article en

Abstract

Alveolar–interstitial syndrome (AIS) is a common ultrasonographic finding in dogs and cats with pulmonary pathology, including cardiogenic pulmonary edema, noncardiogenic pulmonary edema, pneumonia, acute respiratory distress syndrome, and pulmonary contusion. Point-of-care lung ultrasound (LUS) has emerged as a rapid, noninvasive, and repeatable diagnostic tool for identifying AIS in emergency and critical care patients. Despite its increasing clinical adoption, transducer selection remains largely operator-dependent, with limited evidence-based guidance for veterinary applications. This review synthesizes current veterinary and human literature to evaluate how transducer type influences the detection and characterization of AIS in small animals. The acoustic properties, field of view, penetration depth, and resolution trade-offs of linear, curvilinear, and microconvex transducers are discussed in relation to B-line visualization, pleural line assessment, and detection of subpleural consolidations. Comparative performance data, including the results of recent veterinary studies, are integrated to highlight differences in diagnostic sensitivity, specificity, and interobserver reliability. A clinical decision-making framework is proposed, outlining optimal transducer selection by patient size, suspected pathology, and clinical context (triage, monitoring, follow-up). Practical considerations such as transducer availability, equipment ergonomics, and operator training are addressed. Knowledge gaps and future research priorities, including the role of portable devices and AI-assisted image interpretation, are identified. By consolidating the available evidence, this review aims to standardize and optimize transducer selection in veterinary lung ultrasound, improving diagnostic accuracy, accelerating clinical decision-making, and ultimately enhancing patient outcomes in small animal emergency and critical care.

Frontiers in Veterinary ScienceVol. 13
University of Calgary (CA), Partners In Care (US), Dermatology Specialists (US), Colorado State University (US)
Peace, Justice and strong institutions
Openalex Percentile: Top 11%
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.