Evaluation of real-ear to coupler difference (RECD) Values and Test-Retest Reliability in 0.4 cc and 2 cc Coupler Measurements in Young Adults

Objectives: The aim of this study was to obtain normative data and examine test-retest reliabilities in HA-2 2cc and 0.4 cc coupler RECD measurements in the young adult Turkish population.Materials and Methods: In this study, 36 participants (17 females, 19 males), aged between 20 and 26 years (mean age = 21.80, SD = 1.27), with normal otoscopic findings, normal bilateral hearing, and no history of outer or middle ear surgery, were evaluated. HA-2 2cc and 0.4 cc RECD measurements, as well as retest measurements, were conducted on both ears of the participants by using insert phones and foam tip.Results: A statistically significant positive correlation was observed between the HA-2 2 cc and 0.4 cc RECD test–retest measurements. For the 2 cc RECD test–retest results, reliability was found to be moderate at 125 Hz and 10 kHz, excellent at 3 kHz, and good at the other frequencies. For the 0.4 cc RECD test–retest results, reliability was moderate at 1 kHz, 1.5 kHz, 2 kHz, and 10 kHz, and good at the other frequencies. No interaural differences were found in the RECD values obtained with either coupler. A significant difference between male and female participants was observed only at 250 Hz for the 2 cc RECD test results, and at 125 Hz and 250 Hz for the 0.4 cc RECD test results. Across all frequencies, the 2 cc RECD values were higher than the 0.4 cc RECD values.Conclusion: HA-2 2 cc and 0.4 cc RECD measurements by using insert phones and foam tip are repeatable and clinically reliable methods in young adults.

Authors

Institutions

Publication Details

Journal
Hacettepe Üniversitesi Sağlık Bilimleri Fakültesi Dergisi
Published
2026-04-30
DOI
https://doi.org/10.21020/husbfd.1783593
Primary Topic
Ear Surgery and Otitis Media
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of real-ear to coupler difference (RECD) Values and Test-Retest Reliability in 0.4 cc and 2 cc Coupler Measurements in Young Adults

Samet Kılıç, Mehmet Aslan, Murat Şahin, Leyla Kiraz et al.
Hacettepe Üniversitesi Sağlık Bilimleri Fakültesi Dergisi
Ear Surgery and Otitis Media
article

Evaluation of real-ear to coupler difference (RECD) Values and Test-Retest Reliability in 0.4 cc and 2 cc Coupler Measurements in Young Adults

Samet Kılıç, Mehmet Aslan, Murat Şahin, Leyla Kiraz, Zeynep Sultan Evin, Zehra Güneş, Elifnur Tüdün
article en

Abstract

Objectives: The aim of this study was to obtain normative data and examine test-retest reliabilities in HA-2 2cc and 0.4 cc coupler RECD measurements in the young adult Turkish population.Materials and Methods: In this study, 36 participants (17 females, 19 males), aged between 20 and 26 years (mean age = 21.80, SD = 1.27), with normal otoscopic findings, normal bilateral hearing, and no history of outer or middle ear surgery, were evaluated. HA-2 2cc and 0.4 cc RECD measurements, as well as retest measurements, were conducted on both ears of the participants by using insert phones and foam tip.Results: A statistically significant positive correlation was observed between the HA-2 2 cc and 0.4 cc RECD test–retest measurements. For the 2 cc RECD test–retest results, reliability was found to be moderate at 125 Hz and 10 kHz, excellent at 3 kHz, and good at the other frequencies. For the 0.4 cc RECD test–retest results, reliability was moderate at 1 kHz, 1.5 kHz, 2 kHz, and 10 kHz, and good at the other frequencies. No interaural differences were found in the RECD values obtained with either coupler. A significant difference between male and female participants was observed only at 250 Hz for the 2 cc RECD test results, and at 125 Hz and 250 Hz for the 0.4 cc RECD test results. Across all frequencies, the 2 cc RECD values were higher than the 0.4 cc RECD values.Conclusion: HA-2 2 cc and 0.4 cc RECD measurements by using insert phones and foam tip are repeatable and clinically reliable methods in young adults.

Hacettepe Üniversitesi Sağlık Bilimleri Fakültesi DergisiVol. 13(1)
Trakya University (TR), Inonu University (TR)
Quality Education
Openalex Percentile: Top 7%
Ear Surgery and Otitis Media
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of real-ear to coupler difference (RECD) Values and Test-Retest Reliability in 0.4 cc and 2 cc Coupler Measurements in Young Adults — Samet Kılıç, Mehmet Aslan, et al. · Hacettepe Üniversitesi Sağlık Bilimleri Fakültesi Dergisi (2026) | TGRS Research Map | TGRS